EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Hemodynamic Response to Intubation With 4 Different Laryngoscopes in Coronary Artery Bypass Graft Surgery: A Randomized Trial

Hasan Alp Mermer, Munise Yildiz, Mahmut Sami Tutar, Mehmet Akif Yazar, Betul Kozanhan

Journal of Cardiothoracic and Vascular Anesthesia · 2026-08 · 40 (8) · 2332-2340

DOI: 10.1053/j.jvca.2026.03.050 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2026-08. Verfasst von Hasan Alp Mermer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Reanimation, University of Health Sciences, Konya City Hospital, Konya, Turkey. Electronic address: dr.halp@hotmail.…. Hauptthemen laut MEDLINE: Coronary Artery Bypass, Intubation, Intratracheal, Laryngoscopes, Hemodynamics. Die Arbeit nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES To evaluate whether different laryngoscope types influence the hemodynamic stress response to tracheal intubation in adult patients undergoing elective coronary artery bypass graft (CABG) surgery. DESIGN Prospective, randomized, controlled clinical trial. SETTING University-affiliated tertiary care hospital. PARTICIPANTS A total of 112 adult patients scheduled for elective CABG surgery with no anticipated difficult airway. INTERVENTIONS Patients were randomly assigned to tracheal intubation using a Macintosh laryngoscope, C-MAC videolaryngoscope, EzVision videolaryngoscope, or McGrath videolaryngoscope under a standardized deep anesthesia protocol. MEASUREMENTS AND MAIN RESULTS Hemodynamic parameters were recorded at predefined time points. The primary outcome was the hemodynamic stress response as changes in mean arterial pressure (ΔMAP) and heart rate (ΔHR) between measurements obtained after anesthesia induction but before neuromuscular blockade (T2) and those obtained 1 minute after tracheal intubation (T4). Mean ΔMAP values were 20.8 ± 19.4 mmHg in the Macintosh group, 26.3 ± 13.6 mmHg in the C-MAC group, 21.8 ± 12.4 mmHg in the EzVision group, and 28.4 ± 11.9 mmHg in the McGrath group (p = 0.168). Corresponding ΔHR values were 7.4 ± 8.2 bpm, 6.1 ± 10.6 bpm, 8.6 ± 16.4 bpm, and 7.5 ± 7.7 bpm, respectively (p = 0.844). When hemodynamic stress response was defined as an increase of ≥10 mmHg in MAP and/or ≥10 beats per minute in heart rate, its incidence was 28.5%, 37.0%, 42.8%, and 42.8% in the Macintosh, C-MAC, EzVision, and McGrath groups, respectively (p = 0.653). Intubation time differed significantly among the groups (median [interquartile range]: 15 [11-18], 19 [12-22], 22 [15-28], and 16 [12-19] seconds, respectively; p < 0.001), whereas intubation success rates and complication profiles were similar across groups. CONCLUSIONS Videolaryngoscopes conferred no hemodynamic advantage over direct laryngoscopy during intubation in deeply anesthetized patients undergoing CABG. Adequate anesthesia depth and pharmacologic modulation likely play a more prominent role than device type in blunting intubation stress.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary Artery BypassIntubation, IntratrachealLaryngoscopesHemodynamicsHumansFemaleMaleProspective StudiesAgedMiddle AgedHeart RateLaryngoscopy

Stichwörter der Autor:innen

coronary artery bypass graftinghemodynamic responsetracheal intubationvideolaryngoscopy

Autor:innen und Institutionen

  • Department of Anesthesiology and Reanimation, University of Health Sciences, Konya City Hospital, Konya, Turkey. Electronic address: dr.halp@hotmail.com.
  • Department of Anesthesiology and Reanimation, University of Health Sciences, Konya City Hospital, Konya, Turkey.
  • Department of Anesthesiology and Reanimation, University of Health Sciences, Konya City Hospital, Konya, Turkey; Outcomes Research Consortium, Houston, Texas, USA.

Zitieren

APA

Mermer, H. A., Yildiz, M., Tutar, M. S., Yazar, M. A., & Kozanhan, B. (2026). Hemodynamic Response to Intubation With 4 Different Laryngoscopes in Coronary Artery Bypass Graft Surgery: A Randomized Trial. Journal of Cardiothoracic and Vascular Anesthesia, 40(8), 2332-2340. https://doi.org/10.1053/j.jvca.2026.03.050

Vancouver

Mermer HA, Yildiz M, Tutar MS, Yazar MA, Kozanhan B. Hemodynamic Response to Intubation With 4 Different Laryngoscopes in Coronary Artery Bypass Graft Surgery: A Randomized Trial. Journal of Cardiothoracic and Vascular Anesthesia. 2026;40(8):2332-2340. doi:10.1053/j.jvca.2026.03.050

BibTeX
@article{Mermer2026,
  author = {Mermer, Hasan Alp and Yildiz, Munise and Tutar, Mahmut Sami and Yazar, Mehmet Akif and Kozanhan, Betul},
  title = {Hemodynamic Response to Intubation With 4 Different Laryngoscopes in Coronary Artery Bypass Graft Surgery: A Randomized Trial},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2026},
  volume = {40},
  number = {8},
  pages = {2332--2340},
  doi = {10.1053/j.jvca.2026.03.050}
}
Kostenlos starten →