EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Reliability of Noninvasive Blood Pressure Monitoring During Atrial Fibrillation Ablation Under General Anesthesia

Jonathon Schwartz, Mohammed Al-Sadawi, Daniel Mattimore, Abhijeet Singh, Andreas Kalogeropoulos

Journal of Cardiothoracic and Vascular Anesthesia · 2026-07 · 40 (7) · 2026-2033

DOI: 10.1053/j.jvca.2026.03.003 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2026-07. Verfasst von Jonathon Schwartz und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Stony Brook University Hospital, Stony Brook, NY. Electronic address: Jonathon.schwartz@stonybrookmedicine.edu. Hauptthemen laut MEDLINE: Atrial Fibrillation, Anesthesia, General, Catheter Ablation, Monitoring, Intraoperative. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES To evaluate the accuracy and reliability of noninvasive blood pressure (NIBP) monitoring compared to invasive blood pressure (IBP) measurements during atrial fibrillation (AF) ablation under general anesthesia, and to determine whether cardiac rhythm influences NIBP performance. DESIGN A retrospective observational cohort study. SETTING A tertiary academic medical center. PARTICIPANTS Ninety adult patients undergoing endovascular AF ablation between June 2022 and March 2023, with paired NIBP and IBP measurements recorded during both sinus rhythm and AF. INTERVENTIONS No interventions were administered for study purposes. All patients received standard general anesthesia and intraoperative monitoring, including radial arterial catheter placement and oscillometric NIBP cuff measurements. MEASUREMENTS AND MAIN RESULTS A total of 1,158 paired NIBP-IBP measurements were analyzed. NIBP underestimated systolic BP by 3.5 mmHg and overestimated diastolic and mean arterial pressures by 2.3 mmHg and 1.4 mmHg, respectively (all p < 0.05). Within-subject variability was highest for systolic BP (SD = 12.3 mmHg). Cardiac rhythm did not significantly affect agreement, though AF and paced rhythm were associated with increased systolic error in univariate models. Ventilation mode and vasopressor use also influenced discrepancies. Intraclass correlation coefficients ranged from 0.73 to 0.84 across BP types. CONCLUSIONS While rhythm did not significantly alter NIBP reliability, substantial variability-particularly in systolic measurements-limits its interchangeability with IBP during AF ablation. These findings support cautious use of NIBP in high-risk procedural settings and highlight the need for further validation in special populations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationAnesthesia, GeneralCatheter AblationMonitoring, IntraoperativeBlood Pressure DeterminationBlood PressureHumansFemaleRetrospective StudiesReproducibility of ResultsMaleMiddle AgedAgedCohort StudiesBlood Pressure Monitors

Stichwörter der Autor:innen

atrial fibrillationendovascular arrhythmia ablationgeneral anesthesiainvasive blood pressurenon-invasive blood pressureoscillometric blood pressureperioperative monitoring

Autor:innen und Institutionen

  • Department of Anesthesiology, Stony Brook University Hospital, Stony Brook, NY. Electronic address: Jonathon.schwartz@stonybrookmedicine.edu.
  • Department of Medicine, Division of Cardiology, Stony Brook University Hospital, Stony Brook, NY.
  • Department of Anesthesiology, Stony Brook University Hospital, Stony Brook, NY.

Zitieren

APA

Schwartz, J., Al-Sadawi, M., Mattimore, D., Singh, A., & Kalogeropoulos, A. (2026). Reliability of Noninvasive Blood Pressure Monitoring During Atrial Fibrillation Ablation Under General Anesthesia. Journal of Cardiothoracic and Vascular Anesthesia, 40(7), 2026-2033. https://doi.org/10.1053/j.jvca.2026.03.003

Vancouver

Schwartz J, Al-Sadawi M, Mattimore D, Singh A, Kalogeropoulos A. Reliability of Noninvasive Blood Pressure Monitoring During Atrial Fibrillation Ablation Under General Anesthesia. Journal of Cardiothoracic and Vascular Anesthesia. 2026;40(7):2026-2033. doi:10.1053/j.jvca.2026.03.003

BibTeX
@article{Schwartz2026,
  author = {Schwartz, Jonathon and Al-Sadawi, Mohammed and Mattimore, Daniel and Singh, Abhijeet and Kalogeropoulos, Andreas},
  title = {Reliability of Noninvasive Blood Pressure Monitoring During Atrial Fibrillation Ablation Under General Anesthesia},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2026},
  volume = {40},
  number = {7},
  pages = {2026--2033},
  doi = {10.1053/j.jvca.2026.03.003}
}