Reliability of Noninvasive Blood Pressure Monitoring During Atrial Fibrillation Ablation Under General Anesthesia
Journal of Cardiothoracic and Vascular Anesthesia · 2026-07 · 40 (7) · 2026-2033
DOI: 10.1053/j.jvca.2026.03.003 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2026-07. Verfasst von Jonathon Schwartz und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Stony Brook University Hospital, Stony Brook, NY. Electronic address: Jonathon.schwartz@stonybrookmedicine.edu. Hauptthemen laut MEDLINE: Atrial Fibrillation, Anesthesia, General, Catheter Ablation, Monitoring, Intraoperative. Die Arbeit nennt 20 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES To evaluate the accuracy and reliability of noninvasive blood pressure (NIBP) monitoring compared to invasive blood pressure (IBP) measurements during atrial fibrillation (AF) ablation under general anesthesia, and to determine whether cardiac rhythm influences NIBP performance. DESIGN A retrospective observational cohort study. SETTING A tertiary academic medical center. PARTICIPANTS Ninety adult patients undergoing endovascular AF ablation between June 2022 and March 2023, with paired NIBP and IBP measurements recorded during both sinus rhythm and AF. INTERVENTIONS No interventions were administered for study purposes. All patients received standard general anesthesia and intraoperative monitoring, including radial arterial catheter placement and oscillometric NIBP cuff measurements. MEASUREMENTS AND MAIN RESULTS A total of 1,158 paired NIBP-IBP measurements were analyzed. NIBP underestimated systolic BP by 3.5 mmHg and overestimated diastolic and mean arterial pressures by 2.3 mmHg and 1.4 mmHg, respectively (all p < 0.05). Within-subject variability was highest for systolic BP (SD = 12.3 mmHg). Cardiac rhythm did not significantly affect agreement, though AF and paced rhythm were associated with increased systolic error in univariate models. Ventilation mode and vasopressor use also influenced discrepancies. Intraclass correlation coefficients ranged from 0.73 to 0.84 across BP types. CONCLUSIONS While rhythm did not significantly alter NIBP reliability, substantial variability-particularly in systolic measurements-limits its interchangeability with IBP during AF ablation. These findings support cautious use of NIBP in high-risk procedural settings and highlight the need for further validation in special populations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Stony Brook University Hospital, Stony Brook, NY. Electronic address: Jonathon.schwartz@stonybrookmedicine.edu.
- Department of Medicine, Division of Cardiology, Stony Brook University Hospital, Stony Brook, NY.
- Department of Anesthesiology, Stony Brook University Hospital, Stony Brook, NY.
Zitieren
APA
Schwartz, J., Al-Sadawi, M., Mattimore, D., Singh, A., & Kalogeropoulos, A. (2026). Reliability of Noninvasive Blood Pressure Monitoring During Atrial Fibrillation Ablation Under General Anesthesia. Journal of Cardiothoracic and Vascular Anesthesia, 40(7), 2026-2033. https://doi.org/10.1053/j.jvca.2026.03.003
Vancouver
Schwartz J, Al-Sadawi M, Mattimore D, Singh A, Kalogeropoulos A. Reliability of Noninvasive Blood Pressure Monitoring During Atrial Fibrillation Ablation Under General Anesthesia. Journal of Cardiothoracic and Vascular Anesthesia. 2026;40(7):2026-2033. doi:10.1053/j.jvca.2026.03.003
BibTeX
@article{Schwartz2026,
author = {Schwartz, Jonathon and Al-Sadawi, Mohammed and Mattimore, Daniel and Singh, Abhijeet and Kalogeropoulos, Andreas},
title = {Reliability of Noninvasive Blood Pressure Monitoring During Atrial Fibrillation Ablation Under General Anesthesia},
journal = {Journal of Cardiothoracic and Vascular Anesthesia},
year = {2026},
volume = {40},
number = {7},
pages = {2026--2033},
doi = {10.1053/j.jvca.2026.03.003}
}
EUVIMED