EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Monitored anesthesia care versus general anesthesia for balloon-in-basket pulsed-field ablation of atrial fibrillation: an age-matched analysis of procedural timing and acute procedural outcomes

Sri Sundaram iD, Nicholas Palmeri, Dan Alyesh, Lukasz Cerbin, Kareena Sundaram, Ariella Rappaport, Andres Javier Dorado Montoya, Henry Zheng, William Choe, J R Stanton, Ahmed F Osman, David N Kenigsberg

Journal of Interventional Cardiac Electrophysiology · 2026

DOI: 10.1007/s10840-026-02443-2 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2026. Verfasst von Sri Sundaram und 11 weiteren Autor:innen. Beteiligte Einrichtung: South Denver Cardiology Associates, AdventHealth, 1000 SouthPark Drive, Littleton, CO, 80111, USA. sris@southdenver.com. Hauptthemen laut MEDLINE: Atrial Fibrillation, Anesthesia, General, Catheter Ablation, Monitoring, Intraoperative. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

General anesthesia (GA) has been the preferred sedation strategy for atrial fibrillation (AF) catheter ablation in the United States, in part because pulsed-field ablation (PFA) systems cause skeletal muscle stimulation and discomfort that can be poorly tolerated under lighter sedation. A recently introduced balloon-in-basket (BiB) PFA system (VOLT) has been reported to produce less muscle stimulation and pain, potentially allowing Monitored Anesthesia Care (MAC) instead of GA. Whether MAC offers procedural efficiency advantages without compromising ablation efficacy in this context has not been well characterized.

Objective

To compare procedural timing, ablation efficacy, and safety between MAC and GA in patients undergoing BiB PFA (VOLT) for AF, using an age-matched design.

Methods

We retrospectively analyzed 39 consecutive MAC cases and a pool of 83 GA cases undergoing VOLT BiB PFA from a two-site electrophysiology registry. Each MAC patient was matched 1:1 to the nearest age available GA patient yielding 39 age-matched controls. Six different time intervals were collected: total room time, pre-procedure setup time, core procedure time, post-procedure turnover time, transseptal-to-left atrial (LA) sheath-out (dwell) time, and ablation catheter dwell time. Total ablation lesions delivered, acute procedural success (isolation of all four pulmonary veins), and procedural complications were also compared. Group comparisons were then made. In addition, EP laboratory facility cost savings and scheduling opportunity cost associated with the observed difference in total room time, using published EP/procedural-suite per-minute cost estimates were also determined.

Results

Total room time (103.5 ± 20.0 vs. 126.2 ± 33.1 min; p = 0.0004), pre-procedure setup time (33.4 ± 10.0 vs. 50.3 ± 28.0 min; p = 0.0007), and post-procedure turnover time (14.8 ± 9.3 vs. 21.4 ± 8.3 min; p = 0.0030) were significantly shorter with MAC. Core procedure time (55.3 ± 20.5 vs. 55.3 ± 23.9 min), transseptal-to-LA-sheath-out time (34.2 ± 12.9 vs. 35.7 ± 18.5 min) did not differ significantly between groups (both p ≥ 0.62). Ablation catheter dwell time was modestly longer with MAC (27.7 ± 11.9 vs. 24.2 ± 15.5 min; p = 0.036). Total ablation lesions delivered (17.6 ± 5.1 vs. 18.8 ± 7.2, p = 0.68) and acute procedural success (39/39 [100%] vs. 39/39 [100%]) were similar between MAC and GA, with no procedural complications in either group. One MAC case (2.6%) was converted to general anesthesia interprocedurally for coughing attributed to airway secretions. Applying published EP/procedural-suite per-minute cost estimates ($29–$60/minute) to the observed 22.7-min reduction in total room time, MAC was associated with an estimated $658–$1,362 in facility cost savings per case, with potential opportunity cost benefit for additional case scheduling.

Conclusion

In an age-matched cohort undergoing BiB PFA (VOLT) for AF, MAC was associated with shorter total room time, pre-procedure setup time, and post-procedure turnover time than GA, with no difference in ablation lesion delivery, acute success, or complications. Anesthesia related time savings with MAC appear concentrated in room logistics rather than the ablation procedure itself, with no detectable difference in acute procedural outcomes in this small cohort, supporting MAC as a reasonable alternative to GA for BiB PFA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationAnesthesia, GeneralCatheter AblationMonitoring, IntraoperativeHumansFemaleMaleTreatment OutcomeRetrospective StudiesMiddle Aged

Stichwörter der Autor:innen

Atrial fibrillationBalloon-in-basket ablationCatheter ablationGeneral anesthesiaMonitored anesthesia careProcedural efficiencyPulsed-field ablationSedation

Autor:innen und Institutionen

  • South Denver Cardiology Associates, AdventHealth, 1000 SouthPark Drive, Littleton, CO, 80111, USA. sris@southdenver.com.
  • South Denver Cardiology Associates, AdventHealth, 1000 SouthPark Drive, Littleton, CO, 80111, USA.
  • College of Arts and Sciences, Washington University in St. Louis, St. Louis, MO, USA.
  • College of Literature, Science, and the Arts, University of Michigan, Ann Arbor, MI, USA.
  • College of Arts and Sciences, Baylor University, Waco, TX, USA.
  • Department of Anesthesiology, HCA East Florida Division, HCA Florida Westside Hospital, Plantation, FL, USA.

ORCID-Profile: Sri Sundaram

Zitieren

APA

Sundaram, S., Palmeri, N., Alyesh, D., Cerbin, L., Sundaram, K., Rappaport, A., Montoya, A. J. D., Zheng, H., Choe, W., Stanton, J. R., Osman, A. F., & Kenigsberg, D. N. (2026). Monitored anesthesia care versus general anesthesia for balloon-in-basket pulsed-field ablation of atrial fibrillation: an age-matched analysis of procedural timing and acute procedural outcomes. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-026-02443-2

Vancouver

Sundaram S, Palmeri N, Alyesh D, Cerbin L, Sundaram K, Rappaport A, et al. Monitored anesthesia care versus general anesthesia for balloon-in-basket pulsed-field ablation of atrial fibrillation: an age-matched analysis of procedural timing and acute procedural outcomes. Journal of Interventional Cardiac Electrophysiology. 2026. doi:10.1007/s10840-026-02443-2

BibTeX
@article{Sundaram2026,
  author = {Sundaram, Sri and Palmeri, Nicholas and Alyesh, Dan and Cerbin, Lukasz and Sundaram, Kareena and Rappaport, Ariella and Montoya, Andres Javier Dorado and Zheng, Henry and Choe, William and Stanton, J R and Osman, Ahmed F and Kenigsberg, David N},
  title = {Monitored anesthesia care versus general anesthesia for balloon-in-basket pulsed-field ablation of atrial fibrillation: an age-matched analysis of procedural timing and acute procedural outcomes},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2026},
  doi = {10.1007/s10840-026-02443-2}
}
Kostenlos starten →