EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of Intraoperative Blood Product Use During Heart Transplantation in Patients Bridged with Impella 5.5 versus Durable Left Ventricular Assist Devices

Anna Bovill Shapiro, Ashley Virginia Fritz, Sean Kiley, Shriya Sharma, Parag Patel, Alexander Heckman, Archer Kilbourne Martin, Rohan Goswami

Journal of Cardiothoracic and Vascular Anesthesia · 2024-11 · 38 (11) · 2567-2575

DOI: 10.1053/j.jvca.2024.04.047 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2024-11. Verfasst von Anna Bovill Shapiro und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Jacksonville, FL; Department of Critical Care Medicine, Mayo Clinic, Jacksonvil…. Hauptthemen laut MEDLINE: Heart-Assist Devices, Heart Transplantation. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To determine if the intraoperative transfusion requirements differ based on the mechanical circulatory device used as a bridge to heart transplantation. DESIGN: A single-center retrospective analysis of intraoperative transfusion requirements in all patients undergoing heart or heart/kidney transplantation between November 2018 and July 2021 who were bridged with a temporary (Impella 5.5) or durable left ventricular assist device (LVAD). SETTING: A tertiary care hospital. PARTICIPANTS: Forty-three adult patients bridged to heart or heart/kidney transplantation with a temporary or durable LVAD between 2018 and 2021 INTERVENTIONS: Recording of baseline characteristics and intraoperative transfusion requirements, including packed red blood cells, fresh frozen plasma, cryoprecipitate, autologous blood salvage, and platelets. The difference in cardiopulmonary bypass times, intensive care unit length of stay, and the vasoactive inotrope score following transplantation were also recorded. MEASUREMENTS AND MAIN RESULTS: The primary outcome was the volume of blood products transfused intraoperatively. Patients who underwent bridge to transplantation using the Impella 5.5 had statistically significant lower median transfusions of cryoprecipitate (155 mL versus 200 mL, p = 0.015), autologous blood salvage (675 mL versus 1,125 mL, p ≤ 0.01), and platelets (412 mL versus 675 mL, p ≤ 0.01). Additionally, there was a trend toward lower transfusion of intraoperative packed red blood cells (4.5 units versus 6.5 units, p = 0.29) and fresh frozen plasma (675 mL versus 800 mL, p = 0.11), but these were not statistically significant. CONCLUSIONS: The results suggest a reduction in certain intraoperative transfusion requirements in patients undergoing heart transplantation bridged with the Impella 5.5 versus durable left ventricular assist device.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesHeart TransplantationHumansMaleFemaleRetrospective StudiesMiddle AgedAdultBlood TransfusionIntraoperative CareAgedHeart Failure

Stichwörter der Autor:innen

Impella 5.5bridge to transplantationheart transplantationleft ventricular assist devicemechanical circulatory supporttransfusion requirements

Autor:innen und Institutionen

  • Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Jacksonville, FL; Department of Critical Care Medicine, Mayo Clinic, Jacksonville, FL. Electronic address: shapiro.anna@mayo.edu.
  • Division of Cardiovascular and Thoracic Anesthesiology, Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Jacksonville, FL.
  • Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Jacksonville, FL; Department of Critical Care Medicine, Mayo Clinic, Jacksonville, FL.
  • Division of Transplantation and Advanced Heart Failure, Mayo Clinic, Jacksonville, FL.
  • Department of Cardiology, Oregon Health and Science University, Portland, OR.

Zitieren

APA

Shapiro, A. B., Fritz, A. V., Kiley, S., Sharma, S., Patel, P., Heckman, A., Martin, A. K., & Goswami, R. (2024). Comparison of Intraoperative Blood Product Use During Heart Transplantation in Patients Bridged with Impella 5.5 versus Durable Left Ventricular Assist Devices. Journal of Cardiothoracic and Vascular Anesthesia, 38(11), 2567-2575. https://doi.org/10.1053/j.jvca.2024.04.047

Vancouver

Shapiro AB, Fritz AV, Kiley S, Sharma S, Patel P, Heckman A, et al. Comparison of Intraoperative Blood Product Use During Heart Transplantation in Patients Bridged with Impella 5.5 versus Durable Left Ventricular Assist Devices. Journal of Cardiothoracic and Vascular Anesthesia. 2024;38(11):2567-2575. doi:10.1053/j.jvca.2024.04.047

BibTeX
@article{Shapiro2024,
  author = {Shapiro, Anna Bovill and Fritz, Ashley Virginia and Kiley, Sean and Sharma, Shriya and Patel, Parag and Heckman, Alexander and Martin, Archer Kilbourne and Goswami, Rohan},
  title = {Comparison of Intraoperative Blood Product Use During Heart Transplantation in Patients Bridged with Impella 5.5 versus Durable Left Ventricular Assist Devices},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2024},
  volume = {38},
  number = {11},
  pages = {2567--2575},
  doi = {10.1053/j.jvca.2024.04.047}
}
Kostenlos starten →