Objective

Radiation dose assessment is an important component of radiological protection in abdominal digital radiography (DR). Reliable estimation of patient radiation dose may contribute to exposure monitoring and support radiation protection practices in clinical radiography. This study aimed to develop a regression-based model for estimating radiation dose using exposure parameters and the manufacturer-specific exposure indicator (S-number).

Methods

Abdominal DR exposures were performed using polymethyl methacrylate (PMMA) phantoms with thicknesses ranging from 15 to 25 cm. Imaging parameters included tube voltages of 65–85 kV and tube current–time products of 16–25 mAs. Radiation dose was measured using calibrated optically stimulated luminescence dosimeters (OSLDs). Correlation analysis and multiple regression modelling were performed to establish a dose prediction equation. The agreement between measured and estimated doses was evaluated using Bland–Altman analysis.

Results

Radiation dose increased with increasing kV and mAs but decreased with increasing S-number. The regression model for dose estimation was: Dose (mGy) = −1.915 + 0.025(kV) + 0.043(mAs) − 8.385(S-number) ⁻¹, with a coefficient of determination (R² = 0.97). Bland–Altman analysis demonstrated good agreement between measured and predicted doses, with a mean bias of 0.019 mGy and limits of agreement ranging from −0.050 to 0.088 mGy.

Conclusion

A regression-based model was successfully developed for estimating radiation dose in abdominal DR using routinely available exposure parameters and S-number. The proposed model demonstrated good agreement with measured dosimetric data and may provide a practical approach for dose assessment and radiation exposure monitoring in digital radiography systems.

Zitieren

APA

Hung, M., & Chen, Y. (2026). Radiation dose estimation model using exposure parameters and S-number in abdominal digital radiography: a phantom study. Radioprotection. https://doi.org/10.1051/radiopro/2026027

Vancouver

Hung M, Chen Y. Radiation dose estimation model using exposure parameters and S-number in abdominal digital radiography: a phantom study. Radioprotection. 2026. doi:10.1051/radiopro/2026027

BibTeX
@article{Hung2026,
  author = {Hung, Mao-Chin and Chen, Ying-Lin},
  title = {Radiation dose estimation model using exposure parameters and S-number in abdominal digital radiography: a phantom study},
  journal = {Radioprotection},
  year = {2026},
  doi = {10.1051/radiopro/2026027}
}
Kostenlos starten →