Turbulence in surgical suction heads as detected by MRI
The Journal of ExtraCorporeal Technology · 2023-06 · 55 (2) · 70-81
DOI: 10.1051/ject/2023015 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of ExtraCorporeal Technology, online erschienen am 28.06.2023. Verfasst von Gunnar Hanekop und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Intensive Care, Emergency Medicine, Pain Therapy, University Medicine, Georg-August-University, Robert-Koch-Strasse 40,…. Hauptthemen laut MEDLINE: Hemolysis, Cardiac Surgical Procedures. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 128 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Blood loss is common during surgical procedures, especially in open cardiac surgery. Allogenic blood transfusion is associated with increased morbidity and mortality. Blood conservation programs in cardiac surgery recommend re-transfusion of shed blood directly or after processing, as this decreases transfusion rates of allogenic blood. But aspiration of blood from the wound area is often associated with increased hemolysis, due to flow induced forces, mainly through development of turbulence.
Methods
We evaluated magnetic resonance imaging (MRI) as a qualitative tool for detection of turbulence. MRI is sensitive to flow; this study uses velocity-compensated T1-weighted 3D MRI for turbulence detection in four geometrically different cardiotomy suction heads under comparable flow conditions (0–1250 mL/min).
Results
Our standard control suction head Model A showed pronounced signs of turbulence at all flow rates measured, while turbulence was only detectable in our modified Models 1–3 at higher flow rates (Models 1 and 3) or not at all (Model 2).
Conclusions
The comparison of flow performance of surgical suction heads with different geometries via acceleration-sensitized 3D MRI revealed significant differences in turbulence development between our standard control Model A and the modified alternatives (Models 1–3). As flow conditions during measurement have been comparable, the specific geometry of the respective suction heads must have been the main factor responsible. The underlying mechanisms and causative factors can only be speculated about, but as other investigations have shown, hemolytic activity is positively associated with degree of turbulence. The turbulence data measured in this study correlate with data from other investigations about hemolysis induced by surgical suction heads. The experimental MRI technique used showed added value for further elucidating the underlying physical phenomena causing blood damage due to non-physiological flow.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Intensive Care, Emergency Medicine, Pain Therapy, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany.
- Max-Planck-Institute for Multidisciplinary Sciences, Am Faßberg 11, 37077 Goettingen, Germany.
- Department of Heart-Thoracic- and Vascular-Surgery, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany.
ORCID-Profile: Jens Frahm, Martin G Friedrich
Zitieren
APA
Hanekop, G., Kollmeier, J. M., Frahm, J., Iwanowski, I., Khabbazzadeh, S., Kutschka, I., Tirilomis, T., Ulrich, C., & Friedrich, M. G. (2023). Turbulence in surgical suction heads as detected by MRI. The Journal of ExtraCorporeal Technology, 55(2), 70-81. https://doi.org/10.1051/ject/2023015
Vancouver
Hanekop G, Kollmeier JM, Frahm J, Iwanowski I, Khabbazzadeh S, Kutschka I, et al. Turbulence in surgical suction heads as detected by MRI. The Journal of ExtraCorporeal Technology. 2023;55(2):70-81. doi:10.1051/ject/2023015
BibTeX
@article{Hanekop2023,
author = {Hanekop, Gunnar and Kollmeier, Jost M and Frahm, Jens and Iwanowski, Ireneusz and Khabbazzadeh, Sepideh and Kutschka, Ingo and Tirilomis, Theodor and Ulrich, Christian and Friedrich, Martin G},
title = {Turbulence in surgical suction heads as detected by MRI},
journal = {The Journal of ExtraCorporeal Technology},
year = {2023},
volume = {55},
number = {2},
pages = {70--81},
doi = {10.1051/ject/2023015}
}
EUVIMED