Quality control and maintenance of intraoperative cell salvage instruments
American Journal of Clinical Pathology · 2025
DOI: 10.1093/ajcp/aqaf027 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Clinical Pathology, 2025. Verfasst von Jae Won Lee und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. Hauptthemen laut MEDLINE: Operative Blood Salvage, Blood Transfusion, Autologous. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
Objectives
Intraoperative cell salvage (ICS) is broadly used in high-risk surgical procedures to facilitate rapid autologous red blood cell transfusion, minimizing the need for allogeneic blood and its associated risks. However, standardized guidelines are lacking for the quality control of ICS devices.
Methods
We retrospectively assessed biannual quality control tests performed on 8 ICS devices at our institution between 2017 and 2023. The quality control assessments included visual inspection for hemolysis, albumin levels, potassium (K+) levels, and free hemoglobin levels, as well as microbial cultures.
Results
Among 90 quality control tests, albumin and K+ levels were consistently within acceptable ranges. However, visual inspections revealed 14 and 20 instances of unacceptable hemolysis and free hemoglobin levels, respectively. Two devices exhibited higher frequencies of these unacceptable outcomes. Most microbial cultures identified contaminants, with Klebsiella pneumoniae being the only notable pathogen. Follow-up simulations demonstrated acceptable performance, indicating equipment reliability.
Conclusions
Our findings highlight the need for standardized quality control protocols for ICS devices. Although current guidelines are limited, our biannual quality control standard is both practical and effective. We hope our findings provide a framework for other institutions aiming to optimize ICS device performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
- Department of Laboratory Medicine, Kangdong Sacred Heart Hospital, Seoul, Korea.
- Department of Laboratory Medicine, Seoul National University Hospital, Seoul, Korea.
ORCID-Profile: Yousun Chung, Han Joo Kim, Dae-Hyun Ko
Zitieren
APA
Lee, J. W., Seo, S. W., Chung, Y., Kim, H., Hwang, S. H., Oh, H. B., Kim, H. J., & Ko, D. H. (2025). Quality control and maintenance of intraoperative cell salvage instruments. American Journal of Clinical Pathology. https://doi.org/10.1093/ajcp/aqaf027
Vancouver
Lee JW, Seo SW, Chung Y, Kim H, Hwang SH, Oh HB, et al. Quality control and maintenance of intraoperative cell salvage instruments. American Journal of Clinical Pathology. 2025. doi:10.1093/ajcp/aqaf027
BibTeX
@article{Lee2025,
author = {Lee, Jae Won and Seo, Suk Won and Chung, Yousun and Kim, Hyungsuk and Hwang, Sang-Hyun and Oh, Heung-Beom and Kim, Han Joo and Ko, Dae-Hyun},
title = {Quality control and maintenance of intraoperative cell salvage instruments},
journal = {American Journal of Clinical Pathology},
year = {2025},
doi = {10.1093/ajcp/aqaf027}
}
EUVIMED