EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Influence of Applied Voltage Waveforms on Ozone Generation and Operating Condition Optimisation in Surface DBD Reactors

Brahim el Khalil Oulad Naoui, Said nemmich, Kamel Nassour, Essama Ahmed Ghaitaoui, Amar Tilmatine, Sherif Salama Mohamed Ghoneim, Amanuel Kumsa Bojer, Sayed Ahmed Nagy, Ahmed Mohammed Attiya Soliman, Ahmed M. Hussein

IET Science, Measurement & Technology · 2026-01 · 20 (1)

DOI: 10.1049/smt2.70070 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IET Science, Measurement & Technology, online erschienen am 05.05.2026. Verfasst von Brahim el Khalil Oulad Naoui und 9 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Surface dielectric barrier discharge (SDBD) ozone generators are a promising technology for industrial water treatment as well as air purification; however, they are under‐studied. In this experimental study, three types of AC voltage waveforms (triangular, rectangular and sinusoidal) are compared to ozone generation and energy performance in the SDBD reactor. The optimal waveform was triangular, with an ozone concentration of 12 mg/L and an efficiency of 120 g/kWh. The second was the sinusoidal waveform (120 mg/L and 95 g/kWh, respectively). The most typical was the square waveform, with the rectangular one less effective. The optimum operating conditions are as follows (by response surface methodology (RSM)): V = 7.84 kV, f = 202.86 Hz (η = 114.76 g/kWh) and V = 8.99 kV, f = 849.7 Hz (OC = 132.163 mg/L). This study highlights the importance of optimal waveform selection and systematic parameter tuning to improve ozone generation performance while minimising energy consumption for practical industrial SDBD applications.

Zitieren

APA

Naoui, B. E. K. O., nemmich, S., Nassour, K., Ghaitaoui, E. A., Tilmatine, A., Ghoneim, S. S. M., Bojer, A. K., Nagy, S. A., Soliman, A. M. A., & Hussein, A. M. (2026). Influence of Applied Voltage Waveforms on Ozone Generation and Operating Condition Optimisation in Surface DBD Reactors. IET Science, Measurement & Technology, 20(1). https://doi.org/10.1049/smt2.70070

Vancouver

Naoui BEKO, nemmich S, Nassour K, Ghaitaoui EA, Tilmatine A, Ghoneim SSM, et al. Influence of Applied Voltage Waveforms on Ozone Generation and Operating Condition Optimisation in Surface DBD Reactors. IET Science, Measurement & Technology. 2026;20(1). doi:10.1049/smt2.70070

BibTeX
@article{Naoui2026,
  author = {Naoui, Brahim el Khalil Oulad and nemmich, Said and Nassour, Kamel and Ghaitaoui, Essama Ahmed and Tilmatine, Amar and Ghoneim, Sherif Salama Mohamed and Bojer, Amanuel Kumsa and Nagy, Sayed Ahmed and Soliman, Ahmed Mohammed Attiya and Hussein, Ahmed M.},
  title = {Influence of Applied Voltage Waveforms on Ozone Generation and Operating Condition Optimisation in Surface DBD Reactors},
  journal = {IET Science, Measurement & Technology},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1049/smt2.70070}
}
Kostenlos starten →