EUVIMEDEUVIMED entdecken
Crossref

Impact of applied voltage, air gap, and ground arrangement on discharge power and dielectric capacitance in a volume DBD plasma

Reetesh Borpatra Gohain, Subir Biswas

Physica Scripta · 01.02.2025 · 100 (2) · 025604

DOI: 10.1088/1402-4896/ada3f3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physica Scripta, online erschienen am 14.01.2025. Verfasst von Reetesh Borpatra Gohain und 1 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Indian Council of Medical Research.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrical parameters such as total equivalent capacitance, dielectric capacitance, and average discharge power of a dielectric barrier discharge (DBD)-cold atmospheric plasma (CAP) setup have been determined and their dependency on the applied voltage, air gap, and ground arrangement have been investigated. Considering a more practical scenario of DBD-CAP application in material processing and biomedical fields, three different ground arrangements: (i) bare ground, (ii) glass slide covered ground and (iii) water in a petri dish on the ground electrode have been considered in this study. The electrical parameters are determined by interpreting the charge-voltage (Q-V) plot of the DBD-CAP obtained experimentally. The value of effective dielectric capacitance ( ζ d ) determined from Q-V plot at a lower applied voltage is less, and approaches the geometrically calculated value ( C d ) at higher applied voltage which signifies the DBD discharge occurs from the partial area of the electrode surface. Discharge power and discharge efficiency increase with the applied voltage ( V a ). Empirical fit of the obtained discharge power shows the increase is proportional to ( V a − B ) 2 , where the value of constant B is close to the value of threshold voltage for the discharge.

Förderung

  • Indian Council of Medical Research

Zitieren

APA

Gohain, R. B., & Biswas, S. (2025). Impact of applied voltage, air gap, and ground arrangement on discharge power and dielectric capacitance in a volume DBD plasma. Physica Scripta, 100(2), 025604. https://doi.org/10.1088/1402-4896/ada3f3

Vancouver

Gohain RB, Biswas S. Impact of applied voltage, air gap, and ground arrangement on discharge power and dielectric capacitance in a volume DBD plasma. Physica Scripta. 2025;100(2):025604. doi:10.1088/1402-4896/ada3f3

BibTeX
@article{Gohain2025,
  author = {Gohain, Reetesh Borpatra and Biswas, Subir},
  title = {Impact of applied voltage, air gap, and ground arrangement on discharge power and dielectric capacitance in a volume DBD plasma},
  journal = {Physica Scripta},
  year = {2025},
  volume = {100},
  number = {2},
  pages = {025604},
  doi = {10.1088/1402-4896/ada3f3}
}
Kostenlos starten →