Optimized Integration of Solar Photovoltaic‐Based Distributed Generation for Reliability Enhancement and Operational Configuration of Overloaded Distribution Networks

Muhammad Tamoor, Abdul Rauf Bhatti, Muhammad Farhan, Mohammad Rashed M. Altimania, Hafiz Mudassir Munir, William Holderbaum

IET Renewable Power Generation · 2026-01 · 20 (1)

DOI: 10.1049/rpg2.70274 ↗

At a glance

Journal article in IET Renewable Power Generation, published online on 2026-05-18. Written by Muhammad Tamoor and 5 co-authors. 70 references. The full text is freely available (open access, CC BY 4.0).

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The rising energy demand and deteriorating infrastructure of conventional electrical grids have increased the importance of a robust and efficient distributed generation (DG) system. This research proposes a method for performance improvement of electrical distribution networks by the strategic integration of DG utilizing a photovoltaic power plant (PVPP). A comprehensive load flow analysis (LFA) of the electrical system is conducted using the Newton‐Raphson (NR) approach in electrical transient analyzer program (ETAP) simulation software. LFA indicates severe conditions in the electrical network that include overloaded transformers and distribution lines, low PF and inappropriate voltage profiles on the demand side. To address these issues without modifying the network structure, DG utilizing PVPP is strategically integrated into an existing electric distribution system. The reconfigured system indicates significant improvements like the PF increasing near unity, the voltage profile improving, and line losses significantly decreasing. Furthermore, overloaded distribution lines and transformers are restored to normal operating conditions. The transformer loadings have decreased by significant levels of 5.9, 5.2 and 5.1%. Before the integration of solar PVPP, the PF at the 1.60 MW load was 0.83, which improved to 0.96 after the proposed strategic integration. The improvement in voltage magnitudes across different loads, consumer LT and HT buses using PVPP, ranges from 0.669–1.491%. Similarly, the line losses at cable 1 have been reduced by up to 39.65% and the voltage drop at Load Bus‐5 has been reduced from 0.23–1.72%. Thus, the obtained results confirm that PVPP can play a pivotal role in modernizing electric systems, enhancing system reliability, and reducing carbon footprints.

Cite

APA

Tamoor, M., Bhatti, A. R., Farhan, M., Altimania, M. R. M., Munir, H. M., & Holderbaum, W. (2026). Optimized Integration of Solar Photovoltaic‐Based Distributed Generation for Reliability Enhancement and Operational Configuration of Overloaded Distribution Networks. IET Renewable Power Generation, 20(1). https://doi.org/10.1049/rpg2.70274

Vancouver

Tamoor M, Bhatti AR, Farhan M, Altimania MRM, Munir HM, Holderbaum W. Optimized Integration of Solar Photovoltaic‐Based Distributed Generation for Reliability Enhancement and Operational Configuration of Overloaded Distribution Networks. IET Renewable Power Generation. 2026;20(1). doi:10.1049/rpg2.70274

BibTeX
@article{Tamoor2026,
  author = {Tamoor, Muhammad and Bhatti, Abdul Rauf and Farhan, Muhammad and Altimania, Mohammad Rashed M. and Munir, Hafiz Mudassir and Holderbaum, William},
  title = {Optimized Integration of Solar Photovoltaic‐Based Distributed Generation for Reliability Enhancement and Operational Configuration of Overloaded Distribution Networks},
  journal = {IET Renewable Power Generation},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1049/rpg2.70274}
}
Start for free →