EUVIMEDOntdek EUVIMED
Open access · CC BY 4.0

Analysis of Subsequent Commutation Failures Caused by Valve‐Side Single‐Phase‐to‐Ground Faults in Hybrid Cascaded HVDC Systems and Corresponding Suppression Measures

Tao Zheng, Yuting Xue

IET Renewable Power Generation · 2026-01 · 20 (1)

DOI: 10.1049/rpg2.70246 ↗

At a glance

Journal article in IET Renewable Power Generation, published online on 2026-04-16. Written by Tao Zheng and 1 co-authors. 35 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Natural Science Foundation of China.

SamenvattingBibliografische gegevensCiteRelated studies

Abstract (original language)

Combining advantages of conventional high‐voltage direct‐current (HVDC) and flexible HVDC, the hybrid cascaded HVDC system adopts a structure where a line commutated converter (LCC) and a modular multilevel converter (MMC) are cascaded on the inverter side. The valve‐side single‐phase‐to‐ground (SPG) fault is one of the most critical issues affecting the safe operation of hybrid cascade HVDC systems. However, impacts of valve‐side SPG faults in hybrid cascade HVDC systems have not been thoroughly investigated. This paper first analyses the characteristics of a valve‐side SPG fault of the MMC converter transformer and the generation mechanism of the fault‐induced inrush current (FIIC). The impact of FIIC on the commutation within the LCC inverter is investigated. It is indicated that the harmonics in the FIIC cause voltage distortion on the LCC inverter AC bus, thereby leading to the subsequent commutation failure. Considering the insufficiency of the existing protection schemes in mitigating FIIC, the new suppression strategy based on the bypass circuit breaker of the starting resistor with auxiliary thyristor‐pairs is proposed to achieve the purpose of suppressing subsequent commutation failure. Finally, results obtained from the PSCAD/EMTDC platform demonstrate the validity of the theoretical analysis and the practicality of the proposed solution.

Funding

  • National Natural Science Foundation of China

Cite

APA

Zheng, T., & Xue, Y. (2026). Analysis of Subsequent Commutation Failures Caused by Valve‐Side Single‐Phase‐to‐Ground Faults in Hybrid Cascaded HVDC Systems and Corresponding Suppression Measures. IET Renewable Power Generation, 20(1). https://doi.org/10.1049/rpg2.70246

Vancouver

Zheng T, Xue Y. Analysis of Subsequent Commutation Failures Caused by Valve‐Side Single‐Phase‐to‐Ground Faults in Hybrid Cascaded HVDC Systems and Corresponding Suppression Measures. IET Renewable Power Generation. 2026;20(1). doi:10.1049/rpg2.70246

BibTeX
@article{Zheng2026,
  author = {Zheng, Tao and Xue, Yuting},
  title = {Analysis of Subsequent Commutation Failures Caused by Valve‐Side Single‐Phase‐to‐Ground Faults in Hybrid Cascaded HVDC Systems and Corresponding Suppression Measures},
  journal = {IET Renewable Power Generation},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1049/rpg2.70246}
}
Start for free →