EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Corrected complex torque coefficient method for synchronization stability analysis of grid‐connected VSC

Boyuan Zhao, Lei Chen, Yong Min, Yalou Li, Shiyun Xu

IET Renewable Power Generation · 2024-02 · 18 (3) · 412-425

DOI: 10.1049/rpg2.12857 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IET Renewable Power Generation, online erschienen am 26.09.2023. Verfasst von Boyuan Zhao und 4 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sub‐synchronous oscillation of grid‐connected voltage source converter (VSC) dominated by phase locked loop (PLL) is an important stability issue in nowadays power systems. The complex torque coefficient method has been used to investigate the issue because of its advantage of giving insights into source of damping and contributions of different components on damping. However, it is found that the classic complex torque coefficient method is not entirely applicable for stability analysis of VSC because of the proportional term in PLL. This paper proposes a corrected complex torque coefficient method and defines synchronous and damping coefficients. Based on the proposed method, a small‐signal stability criterion is obtained, in which the system stability depends on the sign of corrected damping coefficient. The impacts of different elements on system damping can be quantitatively evaluated through the method. It is drawn that current control loop and line dynamics contribute negative damping, whereas power control loop contributes positive damping. Moreover, the impacts of operating conditions and controller parameters on damping of different elements are analysed. The eigenvalue analyses and electromagnetic transient simulations have verified the theoretical analysis.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhao, B., Chen, L., Min, Y., Li, Y., & Xu, S. (2024). Corrected complex torque coefficient method for synchronization stability analysis of grid‐connected VSC. IET Renewable Power Generation, 18(3), 412-425. https://doi.org/10.1049/rpg2.12857

Vancouver

Zhao B, Chen L, Min Y, Li Y, Xu S. Corrected complex torque coefficient method for synchronization stability analysis of grid‐connected VSC. IET Renewable Power Generation. 2024;18(3):412-425. doi:10.1049/rpg2.12857

BibTeX
@article{Zhao2024,
  author = {Zhao, Boyuan and Chen, Lei and Min, Yong and Li, Yalou and Xu, Shiyun},
  title = {Corrected complex torque coefficient method for synchronization stability analysis of grid‐connected VSC},
  journal = {IET Renewable Power Generation},
  year = {2024},
  volume = {18},
  number = {3},
  pages = {412--425},
  doi = {10.1049/rpg2.12857}
}
Kostenlos starten →