Influence of different anodised nanoporous structures on the anti‐icing and electrical properties of transmission Al lines
High Voltage · 2025-02 · 10 (1) · 167-177
DOI: 10.1049/hve2.12471 ↗Kurz gefasst
Fachartikel in der Zeitschrift High Voltage, online erschienen am 04.07.2024. Verfasst von Xu Dai und 9 weiteren Autor:innen. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Ice accumulation of overhead transmission lines can lead to serious damage to power systems. Superhydrophobic nanostructured Al conductors are proposed to replace the de‐icing or ice‐melting equipment for economic advantages, good anti‐icing properties and robust electrical performance. Anodisation under different direct current densities is adopted to fabricate two nanostructures on Al conductors, including the reticular and honeycomb‐like nanoporous structures. Compared to pure Al conductors, the anodised surface of honeycomb‐like nanoporous structures exhibits lower ice adhesion (3.82 kPa) and ice accumulation. Aluminium conductor steel reinforced treated in the proposed method has also been validated to exhibit a significant anti‐glaze icing property. Additionally, corona performance and line loss are experimentally measured and calculated to prove good electrical performance. The 0.27 A Al strand shows the highest corona inception voltage (27.86 kV) and the lowest AC resistance (4.65 Ω/km), which is attributed to the good dielectric property and heat dissipation. Therefore, the proposed anti‐icing transmission conductors show profound application potential for power systems.
Zitieren
APA
Dai, X., Yuan, Y., Xiao, J., Jiang, C., Hua, X., Xiang, H., Zhu, T., Liu, G., Zhou, J., & Liao, R. (2025). Influence of different anodised nanoporous structures on the anti‐icing and electrical properties of transmission Al lines. High Voltage, 10(1), 167-177. https://doi.org/10.1049/hve2.12471
Vancouver
Dai X, Yuan Y, Xiao J, Jiang C, Hua X, Xiang H, et al. Influence of different anodised nanoporous structures on the anti‐icing and electrical properties of transmission Al lines. High Voltage. 2025;10(1):167-177. doi:10.1049/hve2.12471
BibTeX
@article{Dai2025,
author = {Dai, Xu and Yuan, Yuan and Xiao, Jie and Jiang, Chenghao and Hua, Xujiang and Xiang, Huiying and Zhu, Tao and Liu, Guoyong and Zhou, Jiang and Liao, Ruijin},
title = {Influence of different anodised nanoporous structures on the anti‐icing and electrical properties of transmission Al lines},
journal = {High Voltage},
year = {2025},
volume = {10},
number = {1},
pages = {167--177},
doi = {10.1049/hve2.12471}
}