EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Hot-air anti-icing characteristics and anti-icing structures of a zero-stage guide vane

Lifeng Gong, Weiliang Zheng, Yaping Hu, Shuliang Jing, Haoyu Yuan, Chen Wu

AIP Advances · 01.05.2025 · 15 (5)

DOI: 10.1063/5.0259853 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AIP Advances, online erschienen am 15.05.2025. Verfasst von Lifeng Gong und 5 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: The Aeronautical Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

When an aero engine operates under icing conditions, the windward surfaces of its intake components, such as the zero-stage guide vane, are prone to icing, posing a potential flight safety hazard. In this study, we establish a computational model for hot-air anti-icing of a full-scale zero-stage guide vane based on CFX and FENSAP-ICE software and conduct a numerical study on three-dimensional coupled heat transfer for anti-icing and the improvement of anti-icing structures. The computational results demonstrate that under anti-icing conditions, the lowest temperature is observed at the root of the leading edge of the guide vane. Icing predominantly occurs in the water droplets impinging on the area downstream of the stagnation point on the guide vane and in proximity to the root of the suction surface, with ice reaching a maximum thickness of ∼7.21 mm. When the hot-air inlet is shifted toward the leading edge and a deflector is introduced, the anti-icing surface temperature is elevated, the icing area is slightly reduced, and the total ice mass is decreased by ∼14.7% compared to the original model. Furthermore, after designing opening holes near the root of the suction surface to allow the hot air to flow out, the temperature on the guide vane’s surface is significantly increased, and the temperature gradient is reduced. The icing area is markedly decreased, with the maximum ice thickness reduced by ∼3.3 mm, and the total ice mass further decreased by about 33.1%.

Förderung

  • The Aeronautical Science Foundation

Zitieren

APA

Gong, L., Zheng, W., Hu, Y., Jing, S., Yuan, H., & Wu, C. (2025). Hot-air anti-icing characteristics and anti-icing structures of a zero-stage guide vane. AIP Advances, 15(5). https://doi.org/10.1063/5.0259853

Vancouver

Gong L, Zheng W, Hu Y, Jing S, Yuan H, Wu C. Hot-air anti-icing characteristics and anti-icing structures of a zero-stage guide vane. AIP Advances. 2025;15(5). doi:10.1063/5.0259853

BibTeX
@article{Gong2025,
  author = {Gong, Lifeng and Zheng, Weiliang and Hu, Yaping and Jing, Shuliang and Yuan, Haoyu and Wu, Chen},
  title = {Hot-air anti-icing characteristics and anti-icing structures of a zero-stage guide vane},
  journal = {AIP Advances},
  year = {2025},
  volume = {15},
  number = {5},
  doi = {10.1063/5.0259853}
}
Kostenlos starten →