EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Assessing Learning‐Based Reconstructed Liver Surfaces From Partial Point Clouds for Improving Pre‐ to Intra‐Operative 3D to 3D Registration

Nakul Poudel iD, Zixin Yang, Richard Simon, Cristian A Linte iD

Healthcare Technology Letters · 2025-01 · 12 (1)

DOI: 10.1049/htl2.70041 ↗

At a glance

Journal article in Healthcare Technology Letters, published online on 2025-12-09. Written by Nakul Poudel and 3 co-authors. Institution: Center for Imaging Science Rochester Institute of Technology Rochester New York USA. Cited 1 times so far (Crossref); 22 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIGMS NIH HHS, National Institutes of Health, National Science Foundation.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The registration process for fusing pre‐operative information with intra‐operative data collected during image‐guided liver surgery struggles due to partial visibility. Learning‐based partial point cloud‐to‐complete surface generation has shown a promising direction for improving registration outcomes. Yet, the intra‐operative liver surface can undergo significant deformation, leading to geometric discrepancies from its pre‐operative shape and introducing error in the completed intra‐operative surface. It is essential to understand the error introduced during surface generation and its impact on both rigid and non‐rigid registration to ensure robust performance in clinical settings. In this study, we leveraged a VN‐OccNet framework trained in a patient‐specific manner on simulated deformed data to generate complete surfaces from partial observations extracted from five viewpoints across four in vitro liver phantoms. We first analysed the error associated with the generated complete surface mesh from the partial point cloud, then integrated the complete surface generated into Go‐ICP and GMM‐FEM registration. Furthermore, we estimated the registration error separately for visible and invisible regions. Our results indicate that the error in the generated surface is more significant further away from the partially visible liver surface, and it could affect the registration, not only in the invisible region, but to some extent also in the visible region within the camera's field of view.

Subjects

Author keywords

image‐guided liver surgeryregistrationsurface completionuncertainty assessment

Authors and institutions

  • Center for Imaging Science Rochester Institute of Technology Rochester New York USA.
  • Biomedical Engineering Rochester Institute of Technology Rochester New York USA.

ORCID profiles: Nakul Poudel, Cristian A Linte

Funding

  • NIGMS NIH HHS
  • National Institutes of Health
  • National Science Foundation

Cite

APA

Poudel, N., Yang, Z., Simon, R., & Linte, C. A. (2025). Assessing Learning‐Based Reconstructed Liver Surfaces From Partial Point Clouds for Improving Pre‐ to Intra‐Operative 3D to 3D Registration. Healthcare Technology Letters, 12(1). https://doi.org/10.1049/htl2.70041

Vancouver

Poudel N, Yang Z, Simon R, Linte CA. Assessing Learning‐Based Reconstructed Liver Surfaces From Partial Point Clouds for Improving Pre‐ to Intra‐Operative 3D to 3D Registration. Healthcare Technology Letters. 2025;12(1). doi:10.1049/htl2.70041

BibTeX
@article{Poudel2025,
  author = {Poudel, Nakul and Yang, Zixin and Simon, Richard and Linte, Cristian A},
  title = {Assessing Learning‐Based Reconstructed Liver Surfaces From Partial Point Clouds for Improving Pre‐ to Intra‐Operative 3D to 3D Registration},
  journal = {Healthcare Technology Letters},
  year = {2025},
  volume = {12},
  number = {1},
  doi = {10.1049/htl2.70041}
}
Start for free →