EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Contactless and short‐range vital signs detection with doppler radar millimetre‐wave (76–81 GHz) sensing firmware

Pi-Yun Chen, Hsu-Yung Lin, Zi-Heng Zhong, Neng-Sheng Pai, Chien-Ming Li, Chia-Hung Lin iD

Healthcare Technology Letters · 2024-12 · 11 (6) · 427-436

DOI: 10.1049/htl2.12075 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Healthcare Technology Letters, online erschienen am 27.02.2024. Verfasst von Pi-Yun Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering National Chin-Yi University of Technology Taichung City Taiwan. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Vital signs such as heart rate (HR) and respiration rate (RR) are essential physiological parameters that are routinely used to monitor human health and bodily functions. They can be continuously monitored through contact or contactless measurements performed in the home or a hospital. In this study, a contactless Doppler radar W‐band sensing system was used for short‐range, contactless vital sign estimation. Frequency‐modulated continuous wave (FMCW) measurements were performed to reduce the influence of a patient's micromotion. Sensing software was developed that can process the received chirps to filter and extract heartbeat and breathing rhythm signals. The proposed contactless sensing system eliminates the need for the contact electrodes, electric patches, photoelectric sensors, and conductive wires used in typical physiological sensing methods. The system operates at 76–81 GHz in FMCW mode and can detect objects on the basis of changes in frequency and phase. The obtained signals are used to precisely monitor a patient's HR and RR with minimal noise interference. In a laboratory setting, the heartbeats and breathing rhythm signals of healthy young participants were measured, and their HR and RR were estimated through frequency‐ and time‐domain analyses. The experimental results confirmed the feasibility of the proposed W‐band mm‐wave radar for contactless and short‐range continuous detection of human vital signs.

Schlagwörter

Stichwörter der Autor:innen

biomedical measurementhealth carewireless sensor networks

Autor:innen und Institutionen

  • Department of Electrical Engineering National Chin-Yi University of Technology Taichung City Taiwan.
  • Department of Medicine of Chi Mei Medical Center Chien-Ming Li is with the Division of Infectious Diseases Tainan City Taiwan.

ORCID-Profile: Chia-Hung Lin

Zitieren

APA

Chen, P. Y., Lin, H. Y., Zhong, Z. H., Pai, N. S., Li, C. M., & Lin, C. H. (2024). Contactless and short‐range vital signs detection with doppler radar millimetre‐wave (76–81 GHz) sensing firmware. Healthcare Technology Letters, 11(6), 427-436. https://doi.org/10.1049/htl2.12075

Vancouver

Chen PY, Lin HY, Zhong ZH, Pai NS, Li CM, Lin CH. Contactless and short‐range vital signs detection with doppler radar millimetre‐wave (76–81 GHz) sensing firmware. Healthcare Technology Letters. 2024;11(6):427-436. doi:10.1049/htl2.12075

BibTeX
@article{Chen2024,
  author = {Chen, Pi-Yun and Lin, Hsu-Yung and Zhong, Zi-Heng and Pai, Neng-Sheng and Li, Chien-Ming and Lin, Chia-Hung},
  title = {Contactless and short‐range vital signs detection with doppler radar millimetre‐wave (76–81 GHz) sensing firmware},
  journal = {Healthcare Technology Letters},
  year = {2024},
  volume = {11},
  number = {6},
  pages = {427--436},
  doi = {10.1049/htl2.12075}
}
Kostenlos starten →