A Vital Signs Detection Method for Contactless Monitoring Using FMCW Radar
IEEE Sensors Journal · 2026-08 · 26 (15) · 23076-23086
DOI: 10.1109/jsen.2026.3704977 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-08. Verfasst von Yansheng Zhu und 4 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Chongqing Youth Innovation Talent Program, Chongqing Postdoctoral Science Foundation Project.
Abstract (Originalsprache)
In recent years, noncontact vital sign monitoring has garnered widespread attention. This article proposes a vital signs monitoring method using a millimeter-wave multiple-input–multiple-output (MIMO) frequency-modulated continuous-wave (FMCW) radar. The method leverages the MIMO capability of the measurement system’s antennas to combine the received signals using the maximum ratio combining (MRC) method. Then, the adaptive amplitude adjustment (AdAA) technique is applied to remove the interference caused by body movement and harmonic interference, while the fixed bandwidth filtering (FBF) method is presented to eliminate the clutter interference. To mitigate the randomness of the FastICA algorithm during decomposition, an improved FastICA (IFastICA) algorithm is proposed. It calculates the Pearson correlation coefficient (PCC) between the high-frequency heartbeat signal separated by conventional FastICA and the phase-combined signal. The separation result whose coefficient meets a predefined threshold is then taken as the quasi-vital sign signal. The quasi-respiration signal is obtained via bandpass filtering and spectral analysis, while the quasi-heartbeat signal is acquired by bandpass filtering combined with autocorrelation. Experimental results verify that the proposed method outperforms existing approaches.
Förderung
- National Natural Science Foundation of China
- Chongqing Youth Innovation Talent Program
- Chongqing Postdoctoral Science Foundation Project
- Science and Technology Innovation Key Research and Development Program of Chongqing
Zitieren
APA
Zhu, Y., Wang, Y., Luo, L., Xie, L., & Yang, X. (2026). A Vital Signs Detection Method for Contactless Monitoring Using FMCW Radar. IEEE Sensors Journal, 26(15), 23076-23086. https://doi.org/10.1109/jsen.2026.3704977
Vancouver
Zhu Y, Wang Y, Luo L, Xie L, Yang X. A Vital Signs Detection Method for Contactless Monitoring Using FMCW Radar. IEEE Sensors Journal. 2026;26(15):23076-23086. doi:10.1109/jsen.2026.3704977
BibTeX
@article{Zhu2026,
author = {Zhu, Yansheng and Wang, Yong and Luo, Langjuan and Xie, Liangbo and Yang, Xiaolong},
title = {A Vital Signs Detection Method for Contactless Monitoring Using FMCW Radar},
journal = {IEEE Sensors Journal},
year = {2026},
volume = {26},
number = {15},
pages = {23076--23086},
doi = {10.1109/jsen.2026.3704977}
}