An Optimal Cascade Controller for Automatic Generation Control of Deregulated Power Systems Incorporating Hybrid Energy Storage Systems

Sandeep Rangi, Sheilza Jain, Yogendra Arya, Ayyala Kishore Ajay Kumar

IET Generation, Transmission & Distribution · 2026-01 · 20 (1)

DOI: 10.1049/gtd2.70376 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IET Generation, Transmission & Distribution, online erschienen am 30.07.2026. Verfasst von Sandeep Rangi und 3 weiteren Autor:innen. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Automatic generation control (AGC) in deregulated power system (DPS) is critical for maintaining stability amidst diverse generation sources and market dynamics. This study employs the novel Griffon Vulture Optimization Algorithm (GVOA) to cascade tilt integral derivative‐fractional integral with derivative filter (CTID‐I λ DN) controller for AGC in a two‐area DPS comprising thermal, hydro, and gas generating units. The dynamic performance of GVOA‐optimized CTID‐I λ DN is compared with cascade tilt integral derivative‐integral derivative (CTID‐ID) proportional integral derivative (PID), and published PID controllers, demonstrating superior transient response, reduced area frequency deviations, and faster settling times with GVOA‐optimized controllers. Further, various combinations of hybrid energy storage systems (HESS) have been incorporated with GVOA‐driven CTID‐I λ DN for performance comparison, resulting in significant improvements in undershoot/overshoot of area frequencies and tie‐line power deviation. Further, the method is utilized in AGC of a two‐area multi‐source power system incorporating geothermal, hydro, gas, thermal, and diesel units. The efficacy of GVOA driven CTID‐I λ DN controller is rigorously verified across various market transaction scenarios and under system parameter variations. Additionally, the efficacy of HESS is established in the presence of nonlinearities. Dynamic responses confirm the robustness and adaptability of the proposed approach which offers enhanced frequency regulation and reliability for DPS in complex operational environments.

Zitieren

APA

Rangi, S., Jain, S., Arya, Y., & Kumar, A. K. A. (2026). An Optimal Cascade Controller for Automatic Generation Control of Deregulated Power Systems Incorporating Hybrid Energy Storage Systems. IET Generation, Transmission & Distribution, 20(1). https://doi.org/10.1049/gtd2.70376

Vancouver

Rangi S, Jain S, Arya Y, Kumar AKA. An Optimal Cascade Controller for Automatic Generation Control of Deregulated Power Systems Incorporating Hybrid Energy Storage Systems. IET Generation, Transmission & Distribution. 2026;20(1). doi:10.1049/gtd2.70376

BibTeX
@article{Rangi2026,
  author = {Rangi, Sandeep and Jain, Sheilza and Arya, Yogendra and Kumar, Ayyala Kishore Ajay},
  title = {An Optimal Cascade Controller for Automatic Generation Control of Deregulated Power Systems Incorporating Hybrid Energy Storage Systems},
  journal = {IET Generation, Transmission & Distribution},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1049/gtd2.70376}
}
Kostenlos starten →