A review on a novel method for aging evaluation of transformer insulating paper based on methanol
IET Generation, Transmission & Distribution · 2023-05 · 17 (9) · 1955-1971
DOI: 10.1049/gtd2.12784 ↗Kurz gefasst
Fachartikel in der Zeitschrift IET Generation, Transmission & Distribution, online erschienen am 08.02.2023. Verfasst von Qingguo Chen und 3 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 115 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
The insulation paper is a crucial factor for evaluating the insulation status of transformers. The traditional evaluation methods for insulation paper are dissolved gas component content analysis (CO and CO 2 ) and furfural (2‐FAL) content analysis in oil. The detection principle of the former leads to its low accuracy, while the field application effect of the latter is not ideal due to the easy oxidation of furfural and low content. Methanol, result of its good stability and high production compared with other marker products (CO, CO 2 , 2‐FAL) has been investigated as a novel marker for aging evaluation of transformer insulating paper in recent years. The results of the investigation indicated that there is a good correlation between the content of methanol in oil and the degree of polymerization under laboratory conditions, which reflected the insulation aging state of the transformer insulating paper more accurately. This paper summarizes the current research status of methanol formation mechanism, detection methods and aging evaluation in insulating oil, and points out the key problems to be solved and development prospects, hoping to provide relevant reference for aging evaluation of oil immersed power transformer.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Chen, Q., Sun, W., Cheng, S., & Huang, G. (2023). A review on a novel method for aging evaluation of transformer insulating paper based on methanol. IET Generation, Transmission & Distribution, 17(9), 1955-1971. https://doi.org/10.1049/gtd2.12784
Vancouver
Chen Q, Sun W, Cheng S, Huang G. A review on a novel method for aging evaluation of transformer insulating paper based on methanol. IET Generation, Transmission & Distribution. 2023;17(9):1955-1971. doi:10.1049/gtd2.12784
BibTeX
@article{Chen2023,
author = {Chen, Qingguo and Sun, Wei and Cheng, Song and Huang, Guokai},
title = {A review on a novel method for aging evaluation of transformer insulating paper based on methanol},
journal = {IET Generation, Transmission & Distribution},
year = {2023},
volume = {17},
number = {9},
pages = {1955--1971},
doi = {10.1049/gtd2.12784}
}
EUVIMED