Moisture and Aging Degree Evaluation Method for Oil-Paper Insulation Based on HV-FDS Characteristics Analysis

Shilin Shi, Jian Hao, Qian Zeng, Fanghui Yin, Ruijin Liao

IEEE Transactions on Dielectrics and Electrical Insulation · 2024-10 · 31 (5) · 2520-2530

DOI: 10.1109/tdei.2024.3394401 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Dielectrics and Electrical Insulation, 2024-10. Verfasst von Shilin Shi und 4 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 19 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Oil-paper insulation is the “heart” of power transformer, and frequency-domain spectroscopy (FDS) is an efficient method to evaluate the insulation state of it. Nevertheless, traditional FDS test voltage is still at 200 V, and the insulation characteristics of FDS at high voltage (HV) levels are worth exploring. Therefore, this article studies the FDS characteristics of oil-paper insulation at various test voltages and proposed an evaluation method of moisture and aging degree of oil-immersed pressboard based on HV FDS. The results show that with the increase of test voltage, the ${C}'$ of mineral oil increases from 1 mHz to 10 Hz, while oil-immersed pressboard and “liquid-solid” oil-paper insulation decrease below 10 Hz; tan $\delta $ of all samples increases significantly with the increase of test voltage. The tan $\delta $ value at 0.1, 1, and 10 Hz is selected as a characteristic parameter to evaluate the moisture content of oil-immersed pressboard, tan $\delta $ at HV is more sensitive to moisture content compared with that at low voltage, and tan $\delta $ at 0.1 Hz and 7000 V increases 1130 times compared 75 times at 0.1 Hz and 200 V. The integral of tan $\delta $ , ${S}_{\tan \delta }$ , from 0.1 to 10 Hz is selected as parameters to evaluate the aging degree. The oil-immersed pressboard and distribution transformer are tested and evaluated by the above evaluation method, and the results show that the error of moisture content and aging degree evaluation result is less than 10%.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Shi, S., Hao, J., Zeng, Q., Yin, F., & Liao, R. (2024). Moisture and Aging Degree Evaluation Method for Oil-Paper Insulation Based on HV-FDS Characteristics Analysis. IEEE Transactions on Dielectrics and Electrical Insulation, 31(5), 2520-2530. https://doi.org/10.1109/tdei.2024.3394401

Vancouver

Shi S, Hao J, Zeng Q, Yin F, Liao R. Moisture and Aging Degree Evaluation Method for Oil-Paper Insulation Based on HV-FDS Characteristics Analysis. IEEE Transactions on Dielectrics and Electrical Insulation. 2024;31(5):2520-2530. doi:10.1109/tdei.2024.3394401

BibTeX
@article{Shi2024,
  author = {Shi, Shilin and Hao, Jian and Zeng, Qian and Yin, Fanghui and Liao, Ruijin},
  title = {Moisture and Aging Degree Evaluation Method for Oil-Paper Insulation Based on HV-FDS Characteristics Analysis},
  journal = {IEEE Transactions on Dielectrics and Electrical Insulation},
  year = {2024},
  volume = {31},
  number = {5},
  pages = {2520--2530},
  doi = {10.1109/tdei.2024.3394401}
}
Kostenlos starten →