Electro‐optical behaviour of CuFe 2 O 4 @rGO nanocomposite for nonenzymatic detection of uric acid via the electrochemical method
Luminescence · 2023
DOI: 10.1002/bio.4479 ↗Kurz gefasst
Fachartikel in der Zeitschrift Luminescence, 2023. Verfasst von Rahul Verma und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Institute of Science, Banaras Hindu University, Varanasi, Uttar Pradesh, India. Hauptthemen laut MEDLINE: Graphite, Nanocomposites. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: BHU, UGC New Delhi, Banaras Hindu University.
Abstract (Originalsprache)
Uric acid (UA) is a blood and urine component obtained as a metabolic by‐product of purine nucleotides. Abnormalities in UA metabolism cause crystal deposition as monosodium urate and lead to various diseases such as gout, hyperuricemia, Lesch–Nyhan syndrome, etc. Monitoring these diseases requires a rapid, sensitive, selective, and portable detection approach. Therefore, this study demonstrates the hydrothermal synthesis of CuFe 2 O 4 /reduced graphene oxide (rGO) nanocomposite for selective detection of UA. After the nanocomposite synthesis, characterization was performed by X‐ray diffraction spectroscopy, Fourier transform infrared spectroscopy, Raman spectroscopy, X‐ray photoelectron spectroscopy, UV–visible spectrometry, atomic force spectroscopy, scanning electron microscopy, and electrochemical analysis. Furthermore, from the electrochemical analysis using cyclic voltammetry (CV), kinetic studies were carried out by varying the scan rate to obtain the diffusion coefficient, surface concentration, and rate of charge transfer to achieve a calibration curve that indicates the quasi reversible nature of the fabricated electrode with a linear regression coefficient of oxidation (R 2 : 0.9992) and reduction (R 2 : 0.9971) peaks. Moreover, the fabricated nonenzymatic amperometric sensor to detect UA with a linearity (R 2 : 0.9989) of 1–400 μM was highly sensitive (2.75 × 10 −4 mAμM −1 cm −2 ) and had a lower limit of detection (0.01231 μM) at pH 7.5 in phosphate‐buffered saline solution. Therefore, the CuFe 2 O 4 /rGO/ITO‐based nonenzymatic sensor could detect interfering agents and spiked real bovine serum samples with higher sensitivity and selectivity for UA detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Institute of Science, Banaras Hindu University, Varanasi, Uttar Pradesh, India.
- Department of Physics, Institute of Science, Banaras Hindu University, Varanasi, Uttar Pradesh, India.
ORCID-Profile: Kshitij Rb Singh, Ranjana Verma, Jay Singh
Förderung
- BHU
- UGC New Delhi
- Banaras Hindu University
Zitieren
APA
Verma, R., Singh, K. R., Verma, R., & Singh, J. (2023). Electro‐optical behaviour of CuFe 2 O 4 @rGO nanocomposite for nonenzymatic detection of uric acid via the electrochemical method. Luminescence. https://doi.org/10.1002/bio.4479
Vancouver
Verma R, Singh KR, Verma R, Singh J. Electro‐optical behaviour of CuFe 2 O 4 @rGO nanocomposite for nonenzymatic detection of uric acid via the electrochemical method. Luminescence. 2023. doi:10.1002/bio.4479
BibTeX
@article{Verma2023,
author = {Verma, Rahul and Singh, Kshitij Rb and Verma, Ranjana and Singh, Jay},
title = {Electro‐optical behaviour of CuFe 2 O 4 @rGO nanocomposite for nonenzymatic detection of uric acid via the electrochemical method},
journal = {Luminescence},
year = {2023},
doi = {10.1002/bio.4479}
}
EUVIMED