EUVIMEDEUVIMED entdecken
Crossref

Ultrasensitive LC-MS/MS quantitation of the N -nitroso-dabigatran etexilate impurity in dabigatran etexilate mesylate using an electrospray ionization technique

Anant D Yadav iD, Ashish C Alaspure iD, Sandesh R Lodha iD, Amrutlal L Prajapat, Anil H Gore iD

Analytical Methods · 2025 · 17 (8) · 1797-1803

DOI: 10.1039/d4ay01710b ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Methods, 2025. Verfasst von Anant D Yadav und 4 weiteren Autor:innen. Beteiligte Einrichtung: Tarsadia Institute of Chemical Science, Uka Tarsadia University, Bardoli, 394350, Gujarat, India. anilanachem@gmail.com. Hauptthemen laut MEDLINE: Dabigatran, Tandem Mass Spectrometry, Drug Contamination, Spectrometry, Mass, Electrospray Ionization. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A validated and highly sensitive method for quantifying N -nitroso-dabigatran etexilate in dabigatran etexilate mesylate using LC-MS/MS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DabigatranTandem Mass SpectrometryDrug ContaminationSpectrometry, Mass, Electrospray IonizationChromatography, LiquidLimit of DetectionReproducibility of ResultsLiquid Chromatography-Mass Spectrometry

Substanzen

Dabigatran

Autor:innen und Institutionen

  • Tarsadia Institute of Chemical Science, Uka Tarsadia University, Bardoli, 394350, Gujarat, India. anilanachem@gmail.com.
  • Analytical Research and Development, Alkem Laboratories Ltd., Bharuch, 393010, Gujarat, India.
  • Maliba Pharmacy College, Uka Tarsadia University, Maliba Campus, Gopal Vidyanagar, Bardoli, 394350, Gujarat, India.

ORCID-Profile: Anant D Yadav, Ashish C Alaspure, Sandesh R Lodha, Anil H Gore

Zitieren

APA

Yadav, A. D., Alaspure, A. C., Lodha, S. R., Prajapat, A. L., & Gore, A. H. (2025). Ultrasensitive LC-MS/MS quantitation of the N -nitroso-dabigatran etexilate impurity in dabigatran etexilate mesylate using an electrospray ionization technique. Analytical Methods, 17(8), 1797-1803. https://doi.org/10.1039/d4ay01710b

Vancouver

Yadav AD, Alaspure AC, Lodha SR, Prajapat AL, Gore AH. Ultrasensitive LC-MS/MS quantitation of the N -nitroso-dabigatran etexilate impurity in dabigatran etexilate mesylate using an electrospray ionization technique. Analytical Methods. 2025;17(8):1797-1803. doi:10.1039/d4ay01710b

BibTeX
@article{Yadav2025,
  author = {Yadav, Anant D and Alaspure, Ashish C and Lodha, Sandesh R and Prajapat, Amrutlal L and Gore, Anil H},
  title = {Ultrasensitive LC-MS/MS quantitation of the N -nitroso-dabigatran etexilate impurity in dabigatran etexilate mesylate using an electrospray ionization technique},
  journal = {Analytical Methods},
  year = {2025},
  volume = {17},
  number = {8},
  pages = {1797--1803},
  doi = {10.1039/d4ay01710b}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche