Rapid lung ventilation MRI using parahydrogen-induced polarization of propane gas
The Analyst · 2024
DOI: 10.1039/d4an01029a ↗Kurz gefasst
Fachartikel in der Zeitschrift The Analyst, 2024. Verfasst von Md Raduanul H Chowdhury und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, Michigan 48202, USA. chekm…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Lung, Propane, Hydrogen. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: NHLBI NIH HHS, NINDS NIH HHS, Ministry of Science and Higher Education of the Russian Federation.
Abstract (Originalsprache)
The feasibility of ultrafast (1.7 s) ventilation MRI with a 1 × 1 × 50 mm 3 voxel size is demonstrated using hyperpolarized propane gas contrast agent in excised rabbit lungs on a 0.35 T clinical MRI scanner without any scanner modification.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, Michigan 48202, USA. chekmenevlab@gmail.com.
- International Tomography Center, SB RAS, 3A Institutskaya St., Novosibirsk 630090, Russia.
- Boreskov Institute of Catalysis SB RAS, 5 Acad. Lavrentiev Pr., Novosibirsk 630090, Russia.
- Department of Pediatrics, Wayne State University, Detroit, Michigan 48202, USA.
- United Arab Emirates University, Al Ain, United Arab Emirates.
- School of Chemical & Biomolecular Sciences, Materials Technology Center, Southern Illinois University, Carbondale, IL 62901, USA.
Förderung
- NHLBI NIH HHS
- NINDS NIH HHS
- Ministry of Science and Higher Education of the Russian Federation
- National Heart, Lung, and Blood Institute
- Russian Science Foundation
- National Institute of Neurological Disorders and Stroke
- Congressionally Directed Medical Research Programs
- National Science Foundation
Zitieren
APA
Chowdhury, M. R. H., Oladun, C., Ariyasingha, N. M., Samoilenko, A., Bawardi, T., Burueva, D. B., Salnikov, O. G., Kovtunova, L. M., Bukhtiyarov, V. I., Shi, Z., Luo, K., Tan, S., Gelovani, J. G., Koptyug, I. V., Goodson, B. M., & Chekmenev, E. Y. (2024). Rapid lung ventilation MRI using parahydrogen-induced polarization of propane gas. The Analyst. https://doi.org/10.1039/d4an01029a
Vancouver
Chowdhury MRH, Oladun C, Ariyasingha NM, Samoilenko A, Bawardi T, Burueva DB, et al. Rapid lung ventilation MRI using parahydrogen-induced polarization of propane gas. The Analyst. 2024. doi:10.1039/d4an01029a
BibTeX
@article{Chowdhury2024,
author = {Chowdhury, Md Raduanul H and Oladun, Clementinah and Ariyasingha, Nuwandi M and Samoilenko, Anna and Bawardi, Tarek and Burueva, Dudari B and Salnikov, Oleg G and Kovtunova, Larisa M and Bukhtiyarov, Valerii I and Shi, Zhongjie and Luo, Kehuan and Tan, Sidhartha and Gelovani, Juri G and Koptyug, Igor V and Goodson, Boyd M and Chekmenev, Eduard Y},
title = {Rapid lung ventilation MRI using parahydrogen-induced polarization of propane gas},
journal = {The Analyst},
year = {2024},
doi = {10.1039/d4an01029a}
}
EUVIMED