Understanding the different effects of fouling mechanisms on working and reference electrodes in fast-scan cyclic voltammetry for neurotransmitter detection
The Analyst · 2024 · 149 (10) · 3008-3016
DOI: 10.1039/d3an02205f ↗Kurz gefasst
Fachartikel in der Zeitschrift The Analyst, 2024. Verfasst von Jaehyun Jang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea. Hauptthemen laut MEDLINE: Neurotransmitter Agents, Biofouling, Electrochemical Techniques. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, National Research Foundation of Korea, National Institutes of Health.
Abstract (Originalsprache)
The distinct impacts of fouling mechanisms on a carbon fiber microelectrode and an Ag/AgCl reference electrode, affecting their performance in neurotransmitter detection via Fast-scan Cyclic Voltammetry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea.
- Department of Biomedical Engineering, Hanyang University, Seoul 04763, Republic of Korea.
- Department of Chemistry & Biochemistry, The University of Arizona, Tucson, AZ 85721, USA.
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN 55905, USA.
- Division of Engineering, Mayo Clinic, Rochester, MN 55905, USA.
- Department of Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA.
Förderung
- NINDS NIH HHS
- National Research Foundation of Korea
- National Institutes of Health
Zitieren
APA
Jang, J., Cho, H. U., Hwang, S., Kwak, Y., Kwon, H., Heien, M. L., Bennet, K. E., Oh, Y., Shin, H., Lee, K. H., & Jang, D. P. (2024). Understanding the different effects of fouling mechanisms on working and reference electrodes in fast-scan cyclic voltammetry for neurotransmitter detection. The Analyst, 149(10), 3008-3016. https://doi.org/10.1039/d3an02205f
Vancouver
Jang J, Cho HU, Hwang S, Kwak Y, Kwon H, Heien ML, et al. Understanding the different effects of fouling mechanisms on working and reference electrodes in fast-scan cyclic voltammetry for neurotransmitter detection. The Analyst. 2024;149(10):3008-3016. doi:10.1039/d3an02205f
BibTeX
@article{Jang2024,
author = {Jang, Jaehyun and Cho, Hyun-U and Hwang, Sangmun and Kwak, Youngjong and Kwon, Haeun and Heien, Michael L and Bennet, Kevin E and Oh, Yoonbae and Shin, Hojin and Lee, Kendall H and Jang, Dong Pyo},
title = {Understanding the different effects of fouling mechanisms on working and reference electrodes in fast-scan cyclic voltammetry for neurotransmitter detection},
journal = {The Analyst},
year = {2024},
volume = {149},
number = {10},
pages = {3008--3016},
doi = {10.1039/d3an02205f}
}
EUVIMED