Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Nadiah Alyamni und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, The Catholic University of America, Washington, D.C., 20064, USA. Hauptthemen laut MEDLINE: Neuropeptide Y, Electrochemical Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: American Chemical Society, NINDS NIH HHS, NIMH NIH HHS.
Abstract (Originalsprache)
The hormone Neuropeptide Y (NPY) plays critical roles in feeding, satiety, obesity, and weight control. However, its complex peptide structure has hindered the development of fast and biocompatible detection methods. Previous studies utilizing electrochemical techniques with carbon fiber microelectrodes (CFMEs) have targeted the oxidation of amino acid residues like tyrosine to measure peptides. Here, we employ the modified sawhorse waveform (MSW) to enable voltammetric identification of NPY through tyrosine oxidation. Use of MSW improves NPY detection sensitivity and selectivity by reducing interference from catecholamines like dopamine, serotonin, and others compared to the traditional triangle waveform. The technique utilizes a holding potential of −0.2 V and a switching potential of 1.2 V that effectively etches and renews the CFME surface to simultaneously detect NPY and other monoamines with a sensitivity of 5.8 ± 0.94 nA/µM ( n = 5). Furthermore, we observed adsorption-controlled, subsecond NPY measurements with CFMEs and MSW. The effective identification of exogenously applied NPY in biological fluids demonstrates the feasibility of this methodology for in vivo and ex vivo studies. These results highlight the potential of MSW voltammetry to enable fast, biocompatible NPY quantification to further elucidate its physiological roles. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, The Catholic University of America, Washington, D.C., 20064, USA.
- Department of Chemistry, American University, Washington, D.C., 20016, USA.
- Department of Mechanical Engineering, The Catholic University of America, Washington, D.C., 20064, USA.
- Department of Chemistry, American University, Washington, D.C., 20016, USA. zestos@american.edu.
Förderung
- American Chemical Society
- NINDS NIH HHS
- NIMH NIH HHS
- Pittsburgh Conference and Exposition
- Translational Impacts
- District of Columbia Developmental Center for AIDS Research
- National Institute of Neurological Disorders and Stroke
Zitieren
APA
Alyamni, N., Abot, J. L., & Zestos, A. G. (2024). Voltammetric detection of Neuropeptide Y using a modified sawhorse waveform. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05373-y
Vancouver
Alyamni N, Abot JL, Zestos AG. Voltammetric detection of Neuropeptide Y using a modified sawhorse waveform. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05373-y
BibTeX
@article{Alyamni2024,
author = {Alyamni, Nadiah and Abot, Jandro L and Zestos, Alexander G},
title = {Voltammetric detection of Neuropeptide Y using a modified sawhorse waveform},
journal = {Analytical and Bioanalytical Chemistry},
year = {2024},
doi = {10.1007/s00216-024-05373-y}
}
EUVIMED