EUVIMEDEUVIMED entdecken
Crossref

A digital multimeter-based portable photoelectrochemical immunoassay for the detection of cardiac troponin I with enzymatic biocatalytic precipitation

Bizhen Huang, Jing Ran, Ruishen Li, Wei Zhuang, Jiabi Chen, Haixin Guo

The Analyst · 2023

DOI: 10.1039/d3an00465a ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Analyst, 2023. Verfasst von Bizhen Huang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, The First Affiliated Hospital of Xiamen University, Xiamen 361003, Fujian, China. Hauptthemen laut MEDLINE: Myocardial Infarction, Biosensing Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Natural Science Foundation of Fujian Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A portable photoelectrochemical immunoassay for cTnI detection was fabricated based on efficient photocurrent response of Cu 2 O coupling with split-type enzymatic biocatalytic precipitation reaction with a digital multimeter readout.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial InfarctionBiosensing TechniquesHumansTroponin IHydrogen PeroxideImmunoassayEnzyme-Linked Immunosorbent AssayAntibodiesLimit of DetectionElectrochemical Techniques

Substanzen

Troponin IHydrogen PeroxideAntibodies

Autor:innen und Institutionen

  • Department of Dermatology, The First Affiliated Hospital of Xiamen University, Xiamen 361003, Fujian, China.
  • Department of Obstetrics and Gynecology, The First Affiliated Hospital of Xiamen University, Xiamen 361003, Fujian, China.
  • Department of Urology, The Second Affiliated Hospital of Fujian Medical University, Quanzhou 362000, Fujian, China. 9199412@fjmu.edu.cn.
  • Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, Quanzhou 362000, Fujian, China. haixin920@fjmu.edu.cn.

Förderung

  • Natural Science Foundation of Fujian Province

Zitieren

APA

Huang, B., Ran, J., Li, R., Zhuang, W., Chen, J., & Guo, H. (2023). A digital multimeter-based portable photoelectrochemical immunoassay for the detection of cardiac troponin I with enzymatic biocatalytic precipitation. The Analyst. https://doi.org/10.1039/d3an00465a

Vancouver

Huang B, Ran J, Li R, Zhuang W, Chen J, Guo H. A digital multimeter-based portable photoelectrochemical immunoassay for the detection of cardiac troponin I with enzymatic biocatalytic precipitation. The Analyst. 2023. doi:10.1039/d3an00465a

BibTeX
@article{Huang2023,
  author = {Huang, Bizhen and Ran, Jing and Li, Ruishen and Zhuang, Wei and Chen, Jiabi and Guo, Haixin},
  title = {A digital multimeter-based portable photoelectrochemical immunoassay for the detection of cardiac troponin I with enzymatic biocatalytic precipitation},
  journal = {The Analyst},
  year = {2023},
  doi = {10.1039/d3an00465a}
}
Kostenlos starten →