EUVIMEDEUVIMED entdecken
Leserbrief

Intraoperative evaluation of bone resection accuracy in total knee arthroplasty using an augmented reality-based navigation system

Atsushi Sato, Masataka Ota, Toshiharu Miyazawa, Misako Takizawa, Reo Nagasaka, Marika Mukunoki, Kanako Izukashi, Jun Oike, Takayuki Okumo, Saki Yagura, Takayuki Koya, Koji Kanzaki

Archives of Orthopaedic and Trauma Surgery · 2025

DOI: 10.1007/s00402-025-06033-1 ↗

Kurz gefasst

Leserbrief in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2025. Verfasst von Atsushi Sato und 11 weiteren Autor:innen. Beteiligte Einrichtung: Showa Medical University Fujigaoka Hospital, Yokohama, Japan. atsushi@med.showa-u.ac.jp. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Surgery, Computer-Assisted, Augmented Reality. Die Arbeit nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Computer-assisted surgery (CAS) in total knee arthroplasty (TKA) has seen growing adoption, with over 30% of primary TKA procedures in Japan using CAS as of 2021. Augmented reality (AR) navigation has emerged as a novel alternative, providing real-time visualization and high-precision guidance during surgery. However, standardized protocols, long-term outcomes, and quantitative accuracy data remain limited. This study aimed to evaluate the intraoperative bone resection accuracy achieved with an AR-based navigation system during TKA. METHODS: We retrospectively analyzed 100 knees that underwent primary TKA using the NextAR navigation system (Medacta International SA, Switzerland). Bone resection accuracy was assessed by comparing intraoperative cut angles and thicknesses to preoperative plans. Evaluated parameters included femoral coronal, sagittal, and rotational angles; distal and posterior resection thicknesses (medial/lateral); tibial coronal, posterior slope, and rotational angles; tibial resection thicknesses (medial/lateral); and implant size concordance. RESULTS: Mean absolute differences from preoperative plans were as follows: femoral coronal angle 0.46° ± 0.48°, sagittal angle 0.72° ± 0.61°, and rotational angle 0.30° ± 0.33°; distal cut thickness 0.56 ± 0.46 mm (medial) and 0.54 ± 0.49 mm (lateral); posterior condyle cut thickness 0.23 ± 0.35 mm (medial) and 0.35 ± 0.44 mm (lateral). Tibial parameters showed coronal error of 0.64° ± 0.56°, posterior slope 0.66° ± 0.55°, and rotation 0.25° ± 0.60°; resection thickness 0.73 ± 0.69 mm (medial) and 0.79 ± 0.75 mm (lateral). Implant size matched 100% with preoperative planning. CONCLUSION: The AR-based navigation system enabled precise three-dimensional intraoperative assessment and execution of bone resections in TKA. All angular and thickness errors remained within 1° and 1 mm, respectively, confirming high reproducibility and precision across multiple planes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeSurgery, Computer-AssistedAugmented RealityHumansRetrospective StudiesFemaleMaleAgedMiddle AgedAged, 80 and overFemurTibia

Stichwörter der Autor:innen

Augmented reality navigationBone resection accuracyComputer-assisted surgeryOrthopedic technologyThree-dimensional planningTotal knee arthroplasty

Autor:innen und Institutionen

  • Showa Medical University Fujigaoka Hospital, Yokohama, Japan. atsushi@med.showa-u.ac.jp.
  • Showa Medical University Fujigaoka Hospital, Yokohama, Japan.
  • Showa Medical University Koto Toyosu Hospital, Tokyo, Japan.
  • Showa Medical University School of Medicine, Tokyo, Japan.

Zitieren

APA

Sato, A., Ota, M., Miyazawa, T., Takizawa, M., Nagasaka, R., Mukunoki, M., Izukashi, K., Oike, J., Okumo, T., Yagura, S., Koya, T., & Kanzaki, K. (2025). Intraoperative evaluation of bone resection accuracy in total knee arthroplasty using an augmented reality-based navigation system. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-025-06033-1

Vancouver

Sato A, Ota M, Miyazawa T, Takizawa M, Nagasaka R, Mukunoki M, et al. Intraoperative evaluation of bone resection accuracy in total knee arthroplasty using an augmented reality-based navigation system. Archives of Orthopaedic and Trauma Surgery. 2025. doi:10.1007/s00402-025-06033-1

BibTeX
@article{Sato2025,
  author = {Sato, Atsushi and Ota, Masataka and Miyazawa, Toshiharu and Takizawa, Misako and Nagasaka, Reo and Mukunoki, Marika and Izukashi, Kanako and Oike, Jun and Okumo, Takayuki and Yagura, Saki and Koya, Takayuki and Kanzaki, Koji},
  title = {Intraoperative evaluation of bone resection accuracy in total knee arthroplasty using an augmented reality-based navigation system},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2025},
  doi = {10.1007/s00402-025-06033-1}
}
Kostenlos starten →