EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of repeatability and agreement of two optical biometers for intraocular lens power calculation

Irene Martinez Alberquilla, Saga Svensson, Javier Ruiz-Alcocer, David Madrid-Costa, Alberto Dominguez-Vicent, Abinaya Priya Venkataraman

Scientific Reports · 27.09.2024 · 14 (1)

DOI: 10.1038/s41598-024-73206-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Scientific Reports, online erschienen am 27.09.2024. Verfasst von Irene Martinez Alberquilla und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinical and Experimental Eye Research Group, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain. Hauptthemen laut MEDLINE: Lenses, Intraocular, Biometry. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Karolinska Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The repeatability of two biometers (Lenstar-LS900 and Eyestar-900) to measure ocular parameters and intraocular lens (IOL) power calculation, and their agreement were evaluated. 134 eyes of 134 participants were measured thrice with each biometer. Axial length (AL), anterior chamber depth (ACD), lens thickness (LT) and keratometry (K) were evaluated. The IOL power was calculated using different formulas. The repeatability limit (RLimit), the mean differences (MD) and the limits of agreement (LoA) were calculated. The RLimits for all parameters were higher with Lenstar compared to Eyestar. RLimits were lower than 0.50 D except for Barrett Universal II (0.54 D) and Haigis (0.51 D) formulas with the Lenstar. Mean differences were lower than 0.01 mm for AL, ACD and LT, and lower than 0.03 D for K. MD ranged from 0 to 0.02 D for all formulas except for Barrett and Hill. When dividing the sample into subgroups (short, normal and long eyes), the MDs were similar for the IOL power and were lower than 0.03 D, except for the Barrett and Hill formulas. Both biometers provide repeatable biometry and IOL power calculations. The LoA interval for the IOL power calculation was between 0.75 and 1.50D, which was similar among the subgroups.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularBiometryHumansMaleFemaleMiddle AgedAgedReproducibility of ResultsAdultAxial Length, EyeAnterior ChamberRefraction, OcularOptics and Photonics

Stichwörter der Autor:innen

AgreementEyestarIOL power calculationLenstarRepeatability

Autor:innen und Institutionen

  • Clinical and Experimental Eye Research Group, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain.
  • Department of Optometry and Vision, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain.
  • Unit of Optometry, Division of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, 171 77, Sweden.
  • Unit of Optometry, Division of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, 171 77, Sweden. abinaya.venkataraman@ki.se.

Förderung

  • Karolinska Institute

Zitieren

APA

Alberquilla, I. M., Svensson, S., Ruiz-Alcocer, J., Madrid-Costa, D., Dominguez-Vicent, A., & Venkataraman, A. P. (2024). Evaluation of repeatability and agreement of two optical biometers for intraocular lens power calculation. Scientific Reports, 14(1). https://doi.org/10.1038/s41598-024-73206-0

Vancouver

Alberquilla IM, Svensson S, Ruiz-Alcocer J, Madrid-Costa D, Dominguez-Vicent A, Venkataraman AP. Evaluation of repeatability and agreement of two optical biometers for intraocular lens power calculation. Scientific Reports. 2024;14(1). doi:10.1038/s41598-024-73206-0

BibTeX
@article{Alberquilla2024,
  author = {Alberquilla, Irene Martinez and Svensson, Saga and Ruiz-Alcocer, Javier and Madrid-Costa, David and Dominguez-Vicent, Alberto and Venkataraman, Abinaya Priya},
  title = {Evaluation of repeatability and agreement of two optical biometers for intraocular lens power calculation},
  journal = {Scientific Reports},
  year = {2024},
  volume = {14},
  number = {1},
  doi = {10.1038/s41598-024-73206-0}
}
Kostenlos starten →