EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cell-SELEX for aptamer discovery and its utilization in constructing electrochemical biosensor for rapid and highly sensitive detection of Legionella pneumophila serogroup 1

Aysha Shaukat, Amani Chrouda, Saima Sadaf, Fatimah Alhamlan, Shimaa Eissa, Mohammed Zourob

Scientific Reports · 19.06.2024 · 14 (1)

DOI: 10.1038/s41598-024-65075-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Scientific Reports, online erschienen am 19.06.2024. Verfasst von Aysha Shaukat und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Alfaisal University, 11533, Riyadh, Kingdom of Saudi Arabia. Hauptthemen laut MEDLINE: Legionella pneumophila, Biosensing Techniques, SELEX Aptamer Technique, Aptamers, Nucleotide. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Khalifa University of Science, Technology and Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study introduces an innovative electrochemical aptasensor designed for the highly sensitive and rapid detection of Legionella pneumophila serogroup 1 ( L. pneumophila SG1 ), a particularly virulent strain associated with Legionellosis. Employing a rigorous selection process utilizing cell-based systematic evolution of ligands by exponential enrichment (cell-SELEX), we identified new high-affinity aptamers specifically tailored for L. pneumophila SG1 . The selection process encompassed ten rounds of cell-SELEX cycles with live L. pneumophila , including multiple counter-selection steps against the closely related Legionella sub-species . The dissociation constant (K d ) of the highest affinity sequence to L. pneumophila SG1 was measured at 14.2 nM, representing a ten-fold increase in affinity in comparison with the previously reported aptamers. For the development of electrochemical aptasensor, a gold electrode was modified with the selected aptamer through the formation of self-assembled monolayers (SAMs). The newly developed aptasensor exhibited exceptional sensitivity, and specificity in detecting and differentiating various Legionella sp., with a detection limit of 5 colony forming units (CFU)/mL and an insignificant/negligible cross-reactivity with closely related sub-species. Furthermore, the aptasensor effectively detected L. pneumophila SG1 in spiked water samples, demonstrating an appreciable recovery percentage. This study shows the potential of our aptamer-based electrochemical biosensor as a promising approach for detecting L. pneumophila SG1 in diverse environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Legionella pneumophilaBiosensing TechniquesSELEX Aptamer TechniqueAptamers, NucleotideElectrochemical TechniquesSerogroupGoldSensitivity and SpecificityLimit of DetectionHumans

Stichwörter der Autor:innen

AptamerBiosensorsGold electrodesLegionellosisSELEXSquare wave voltammetry

Substanzen

Aptamers, NucleotideGold

Autor:innen und Institutionen

  • Department of Chemistry, Alfaisal University, 11533, Riyadh, Kingdom of Saudi Arabia.
  • School of Biochemistry and Biotechnology, University of the Punjab, Lahore, Pakistan.
  • King Faisal Specialist Hospital and Research Center, Riyadh, Kingdom of Saudi Arabia.
  • Department of Chemistry, Khalifa University of Science and Technology, 127788, Abu Dhabi, United Arab Emirates.
  • Center for Catalysis and Separations, Khalifa University of Science and Technology, 127788, Abu Dhabi, United Arab Emirates.
  • Department of Chemistry, Alfaisal University, 11533, Riyadh, Kingdom of Saudi Arabia. mzourob@alfaisal.edu.

Förderung

  • Khalifa University of Science, Technology and Research

Zitieren

APA

Shaukat, A., Chrouda, A., Sadaf, S., Alhamlan, F., Eissa, S., & Zourob, M. (2024). Cell-SELEX for aptamer discovery and its utilization in constructing electrochemical biosensor for rapid and highly sensitive detection of Legionella pneumophila serogroup 1. Scientific Reports, 14(1). https://doi.org/10.1038/s41598-024-65075-4

Vancouver

Shaukat A, Chrouda A, Sadaf S, Alhamlan F, Eissa S, Zourob M. Cell-SELEX for aptamer discovery and its utilization in constructing electrochemical biosensor for rapid and highly sensitive detection of Legionella pneumophila serogroup 1. Scientific Reports. 2024;14(1). doi:10.1038/s41598-024-65075-4

BibTeX
@article{Shaukat2024,
  author = {Shaukat, Aysha and Chrouda, Amani and Sadaf, Saima and Alhamlan, Fatimah and Eissa, Shimaa and Zourob, Mohammed},
  title = {Cell-SELEX for aptamer discovery and its utilization in constructing electrochemical biosensor for rapid and highly sensitive detection of Legionella pneumophila serogroup 1},
  journal = {Scientific Reports},
  year = {2024},
  volume = {14},
  number = {1},
  doi = {10.1038/s41598-024-65075-4}
}
Kostenlos starten →