EUVIMEDEUVIMED entdecken
Crossref

Reagentless aptamer based on the ultrasensitive and fast response electrochemical capacitive biosensor for EGFR detection in non-small cell lung cancer

Enkhzaya Ganbold, Nam Young Kim, Yu Mi Kim, Parshant Kumar Sharma, Do Nam Lee, Byeolnim Oh, Hyun Soo Kim, Junghan Song, Byungheon Lee, Eun-Seong Kim, Young Kee Shin, Jeong Su Park und 1 weitere

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2025.117319 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Enkhzaya Ganbold und 12 weiteren Autor:innen. Beteiligte Einrichtung: RFIC Bio Centre, Kwangwoon University, 20 Kwangwoon-ro, Nowon-Gu, Seoul 01897, Republic of Korea; Department of Electronics Engineering, Kwangwoon Un…. Hauptthemen laut MEDLINE: Biosensing Techniques, Carcinoma, Non-Small-Cell Lung, Lung Neoplasms, Aptamers, Nucleotide. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 64 Literaturangaben. Gefördert von: Ministry of Health and Welfare, Korea Health Industry Development Institute, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Non-small cell lung cancer (NSCLC) is still the leading cause of lung cancer-related deaths globally, affecting both men and women. Mutations in the epidermal growth factor receptor (EGFR) are most common among patients with NSCLC, especially Asian patients. Here, we introduce an electrochemical capacitive biosensor for the early detection of NSCLC through specific identification of EGFR. A novel and reagentless EGFR aptamer was designed using the systematic evolution of ligands by exponential enrichment (SELEX) process and immobilized on a chromium (Cr)/gold (Au) electrode, with capacitance signals used for detection. The biosensor employs an interdigitated capacitor electrode (IDCE) functionalized with 3-mercaptopropionic acid (MPA), enhancing EGFR aptamer immobilization, while 6-mercapto-1-hexanol (MCH) was used for effective blocking to ensure robust and high-affinity binding to target analytes. The IDCE capacitive biosensor achieved real-time rapid detection within 3 s and demonstrated a detection limit of 0.005 ng/mL for the EGFR peptide, with a dynamic range of 10-11-10-7 ng/mL. Furthermore, the specific EGFR aptamer-immobilized IDCE biosensor was found to be regenerable and reusable up to five times using deionized water. This biosensor offers a rapid, label-free, and highly selective approach for early-stage EGFR detection in NSCLC. Its portability and scalability make it a promising tool for point-of-care diagnostic applications in biomedicine, potentially advancing the field of cancer diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesCarcinoma, Non-Small-Cell LungLung NeoplasmsAptamers, NucleotideErbB ReceptorsElectrochemical TechniquesHumansLimit of DetectionSELEX Aptamer TechniqueGold

Stichwörter der Autor:innen

Biomedical applicationEGFR detection in non-small cell lung cancerRapid detectionRegenerable aptamerReusable interdigitated capacitor electrode

Substanzen

Aptamers, NucleotideErbB ReceptorsEGFR protein, humanGold

Autor:innen und Institutionen

  • RFIC Bio Centre, Kwangwoon University, 20 Kwangwoon-ro, Nowon-Gu, Seoul 01897, Republic of Korea; Department of Electronics Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-Gu, Seoul 01897, Republic of Korea; N…
  • RFIC Bio Centre, Kwangwoon University, 20 Kwangwoon-ro, Nowon-Gu, Seoul 01897, Republic of Korea; Neuroscience Research Institute, JnPharma Inc. Healthcare Innovation Park, Seoul National University College of Medicine,…
  • RFIC Bio Centre, Kwangwoon University, 20 Kwangwoon-ro, Nowon-Gu, Seoul 01897, Republic of Korea; Department of Electronics Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-Gu, Seoul 01897, Republic of Korea.
  • RFIC Bio Centre, Kwangwoon University, 20 Kwangwoon-ro, Nowon-Gu, Seoul 01897, Republic of Korea; Ingenium College of Liberal Arts (Chemistry), Kwangwoon University, 20 Kwangwoon-ro, Nowon-Gu, Seoul 01897, Republic of K…
  • RFIC Bio Centre, Kwangwoon University, 20 Kwangwoon-ro, Nowon-Gu, Seoul 01897, Republic of Korea; Department of Laboratory Medicine, Seoul National University Bundang Hospital, Goomi-ro, Bundanggu, Seongnam City, Gyeong…
  • RFIC Bio Centre, Kwangwoon University, 20 Kwangwoon-ro, Nowon-Gu, Seoul 01897, Republic of Korea; Department of Biochemistry, School of Medicine, Kyungpook National University 680 Guckchaebosang-ro, Jung-gu, Daegu 41944…

Förderung

  • Ministry of Health and Welfare
  • Korea Health Industry Development Institute
  • National Research Foundation of Korea

Zitieren

APA

Ganbold, E., Kim, N. Y., Kim, Y. M., Sharma, P. K., Lee, D. N., Oh, B., Kim, H. S., Song, J., Lee, B., Kim, E. S., Shin, Y. K., Park, J. S., & Kim, S. T. (2025). Reagentless aptamer based on the ultrasensitive and fast response electrochemical capacitive biosensor for EGFR detection in non-small cell lung cancer. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117319

Vancouver

Ganbold E, Kim NY, Kim YM, Sharma PK, Lee DN, Oh B, et al. Reagentless aptamer based on the ultrasensitive and fast response electrochemical capacitive biosensor for EGFR detection in non-small cell lung cancer. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117319

BibTeX
@article{Ganbold2025,
  author = {Ganbold, Enkhzaya and Kim, Nam Young and Kim, Yu Mi and Sharma, Parshant Kumar and Lee, Do Nam and Oh, Byeolnim and Kim, Hyun Soo and Song, Junghan and Lee, Byungheon and Kim, Eun-Seong and Shin, Young Kee and Park, Jeong Su and Kim, Sang Tae},
  title = {Reagentless aptamer based on the ultrasensitive and fast response electrochemical capacitive biosensor for EGFR detection in non-small cell lung cancer},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117319}
}
Kostenlos starten →