EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison between contact diode laser with 980 nm and 1470 nm wavelengths for posterior laryngofissure in pigs

Isaac de Faria Soares Rodrigues, Paulo Francisco Guerreiro Cardoso, Natalia Aparecida Nepomuceno da Silva, Aristides Tadeu Correia, Helio Minamoto, Benoit Jacques Bibas, Natalia de Souza Xavier Costa, Marilia Wellichan Mancini, Marisa Dolhnikoff, Paulo Manuel Pego-Fernandes

Scientific Reports · 2024

DOI: 10.1038/s41598-024-62333-3 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Scientific Reports, 2024. Verfasst von Isaac de Faria Soares Rodrigues und 9 weiteren Autor:innen. Beteiligte Einrichtung: Thoracic Surgery Research Laboratory (LIM-61), Division of Thoracic Surgery, Faculdade de Medicina, Instituto do Coracao, Hospital das Clinicas HCFMU…. Hauptthemen laut MEDLINE: Lasers, Semiconductor, Larynx. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To compare two different wavelengths of the surgical contact diode laser (CDL) for producing a posterior laryngofissure in in-vivo pigs. Anesthetized pigs underwent a tracheostomy and an anterior laryngofissure through a cervicotomy. They were randomly selected for the CDL wavelength and Power, according to the peak of Power set at device (980nm wavelength: Ppeak power of 10 W, 15 W, and 20 W, or 1470 nm wavelength: Ppeak 3 W, 5 W, 7 W, 10 W). At the end of the experiment, the laryngotracheal specimen was extracted and sent for histology and morphometry measurements (incision size, depth, area, and lateral thermal damage). Hemodynamic data and arterial blood gases were recorded during the incisions. Statistical analysis of the comparisons between the parameters and groups had a level of significance of p < 0.05. Twenty-six pigs were divided into CDL 980 nm (n = 11) and 1470 nm (n = 15). There was a greater incision area at the thyroid level in the 980 nm CDL and a wider incision at the trachea level, with a larger distance between mucosa borders. There were no significant differences in the area of lateral thermal damage between the two groups and neither difference among the power levels tested. Both wavelengths tested showed similar results in the various combinations of power levels without significant differences in the lateral thermal damage. The posterior laryngofissure incision can be performed by either of the wavelengths at low and medium power levels without great difference on lateral thermal damage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lasers, SemiconductorLarynxAnimalsSwineLaser TherapyTrachea

Autor:innen und Institutionen

  • Thoracic Surgery Research Laboratory (LIM-61), Division of Thoracic Surgery, Faculdade de Medicina, Instituto do Coracao, Hospital das Clinicas HCFMUSP, Universidade de Sao Paulo, Sao Paulo, SP, Brazil. isaac.rodrigues@…
  • Thoracic Surgery Research Laboratory (LIM-61), Division of Thoracic Surgery, Faculdade de Medicina, Instituto do Coracao, Hospital das Clinicas HCFMUSP, Universidade de Sao Paulo, Sao Paulo, SP, Brazil.
  • Departament of Pathology, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, Brazil.
  • Department of Biophotonics, Institute of Research and Education in the Health Area (NUPEN), Sao Carlos, SP, Brazil.

Zitieren

APA

Rodrigues, I. F. S., Guerreiro Cardoso, P. F., Nepomuceno da Silva, N. A., Correia, A. T., Minamoto, H., Bibas, B. J., Xavier Costa, N. S., Mancini, M. W., Dolhnikoff, M., & Pego-Fernandes, P. M. (2024). Comparison between contact diode laser with 980 nm and 1470 nm wavelengths for posterior laryngofissure in pigs. Scientific Reports. https://doi.org/10.1038/s41598-024-62333-3

Vancouver

Rodrigues IFS, Guerreiro Cardoso PF, Nepomuceno da Silva NA, Correia AT, Minamoto H, Bibas BJ, et al. Comparison between contact diode laser with 980 nm and 1470 nm wavelengths for posterior laryngofissure in pigs. Scientific Reports. 2024. doi:10.1038/s41598-024-62333-3

BibTeX
@article{Rodrigues2024,
  author = {Rodrigues, Isaac de Faria Soares and Guerreiro Cardoso, Paulo Francisco and Nepomuceno da Silva, Natalia Aparecida and Correia, Aristides Tadeu and Minamoto, Helio and Bibas, Benoit Jacques and Xavier Costa, Natalia de Souza and Mancini, Marilia Wellichan and Dolhnikoff, Marisa and Pego-Fernandes, Paulo Manuel},
  title = {Comparison between contact diode laser with 980 nm and 1470 nm wavelengths for posterior laryngofissure in pigs},
  journal = {Scientific Reports},
  year = {2024},
  doi = {10.1038/s41598-024-62333-3}
}
Kostenlos starten →