Single-shot 20-fold expansion microscopy
Nature Methods · 2024-11 · 21 (11) · 2128-2134
DOI: 10.1038/s41592-024-02454-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nature Methods, online erschienen am 11.10.2024. Verfasst von Shiwei Mitchell-Wang und 10 weiteren Autor:innen. Beteiligte Einrichtung: McGovern Institute for Brain Research, Massachusetts Institute of Technology, Cambridge, MA, USA. Hauptthemen laut MEDLINE: Brain. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIA NIH HHS, NIMH NIH HHS, U.S. Department of Health & Human Services | NIH | Office of Extramural Research, National Institutes of Health (OER).
Abstract (Originalsprache)
Expansion microscopy (ExM) is in increasingly widespread use throughout biology because its isotropic physical magnification enables nanoimaging on conventional microscopes. To date, ExM methods either expand specimens to a limited range (~4–10× linearly) or achieve larger expansion factors through iterating the expansion process a second time (~15–20× linearly). Here, we present an ExM protocol that achieves ~20× expansion (yielding
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- McGovern Institute for Brain Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
- Department of Chemistry, Massachusetts Institute of Technology, Cambridge, MA, USA.
- Media Arts and Sciences, Massachusetts Institute of Technology, Cambridge, MA, USA.
- Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, USA.
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA.
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA, USA.
Förderung
- NIA NIH HHS
- NIMH NIH HHS
- U.S. Department of Health & Human Services | NIH | Office of Extramural Research, National Institutes of Health (OER)
- Howard Hughes Medical Institute (HHMI)
- NIBIB NIH HHS
- NIGMS NIH HHS
Zitieren
APA
Mitchell-Wang, S., Shin, T. W., Yoder, H. B., McMillan, R. B., Su, H., Liu, Y., Zhang, C., Leung, K. S., Yin, P., Kiessling, L. L., & Boyden, E. S. (2024). Single-shot 20-fold expansion microscopy. Nature Methods, 21(11), 2128-2134. https://doi.org/10.1038/s41592-024-02454-9
Vancouver
Mitchell-Wang S, Shin TW, Yoder HB, McMillan RB, Su H, Liu Y, et al. Single-shot 20-fold expansion microscopy. Nature Methods. 2024;21(11):2128-2134. doi:10.1038/s41592-024-02454-9
BibTeX
@article{MitchellWang2024,
author = {Mitchell-Wang, Shiwei and Shin, Tay Won and Yoder, Harley B and McMillan, Ryan B and Su, Hanquan and Liu, Yixi and Zhang, Chi and Leung, Kylie S and Yin, Peng and Kiessling, Laura L and Boyden, Edward S},
title = {Single-shot 20-fold expansion microscopy},
journal = {Nature Methods},
year = {2024},
volume = {21},
number = {11},
pages = {2128--2134},
doi = {10.1038/s41592-024-02454-9}
}