EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Adaptive Run‐Length Encoded DCT : A High‐Fidelity Compression Algorithm for Real‐Time Photoacoustic Microscopy Imaging in LabVIEW

Mohsin Zafar, Kamran Avanaki iD

Journal of Biophotonics · 2025

DOI: 10.1002/jbio.70043 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biophotonics, 2025. Verfasst von Mohsin Zafar und 1 weiteren Autor:innen. Beteiligte Einrichtung: The Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Photoacoustic Techniques, Algorithms, Data Compression, Microscopy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIBIB NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous photoacoustic microscopy (PAM) imaging generates large volumes of data, resulting in significant storage demands. Here, we propose a high‐fidelity real‐time compression algorithm for PAM data in LabVIEW by combining Discrete Cosine Transform (DCT) with adaptive thresholding and Run Length Encoding (RLE), which we term Adaptive Run Length Encoded DCT (AR‐DCT) compression. This algorithm reduces data storage requirements while preserving all the details of the images. AR‐DCT ensures real‐time compression, achieving superior compression ratios (CRs) compared to traditional DCT compression. We evaluated the performance of AR‐DCT using in vivo mouse brain imaging data, demonstrating a CR of ~50, with a structural similarity index of 0.980 and minimal degradation in signal quality (percentage‐root‐mean‐square‐difference of 1.345%). The results show that AR‐DCT outperforms traditional DCT, offering higher compression efficiency without significantly sacrificing image quality. These findings suggest that AR‐DCT provides an effective solution for applications requiring continuous experiments, such as cerebral hemodynamics studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Photoacoustic TechniquesAlgorithmsData CompressionMicroscopyImage Processing, Computer-AssistedAnimalsMiceBrainTime FactorsCompression Algorithms

Stichwörter der Autor:innen

LABVIEWbrain imagingphotoacoustic microscopysignal processing

Autor:innen und Institutionen

  • The Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Department of Dermatology and Pediatric, University of Illinois at Chicago, Chicago, Illinois, USA.

ORCID-Profile: Kamran Avanaki

Förderung

  • NIBIB NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Zafar, M., & Avanaki, K. (2025). Adaptive Run‐Length Encoded DCT : A High‐Fidelity Compression Algorithm for Real‐Time Photoacoustic Microscopy Imaging in LabVIEW. Journal of Biophotonics. https://doi.org/10.1002/jbio.70043

Vancouver

Zafar M, Avanaki K. Adaptive Run‐Length Encoded DCT : A High‐Fidelity Compression Algorithm for Real‐Time Photoacoustic Microscopy Imaging in LabVIEW. Journal of Biophotonics. 2025. doi:10.1002/jbio.70043

BibTeX
@article{Zafar2025,
  author = {Zafar, Mohsin and Avanaki, Kamran},
  title = {Adaptive Run‐Length Encoded DCT : A High‐Fidelity Compression Algorithm for Real‐Time Photoacoustic Microscopy Imaging in LabVIEW},
  journal = {Journal of Biophotonics},
  year = {2025},
  doi = {10.1002/jbio.70043}
}
Kostenlos starten →