Consumer wearable devices for evaluation of heart rate control using digoxin versus beta-blockers: the RATE-AF randomized trial
Nature Medicine · 2024-07 · 30 (7) · 2030-2036
DOI: 10.1038/s41591-024-03094-4 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Nature Medicine, online erschienen am 15.07.2024. Verfasst von Simrat K Gill und 19 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Cardiovascular Sciences, University of Birmingham, Birmingham, UK. Hauptthemen laut MEDLINE: Digoxin, Heart Rate, Wearable Electronic Devices, Atrial Fibrillation. Die Arbeit wurde bisher 47-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Heart Foundation (BHF), DH | National Institute for Health Research (NIHR), RCUK | MRC | Medical Research Foundation.
Abstract (Originalsprache)
Consumer-grade wearable technology has the potential to support clinical research and patient management. Here, we report results from the RATE-AF trial wearables study, which was designed to compare heart rate in older, multimorbid patients with permanent atrial fibrillation and heart failure who were randomized to treatment with either digoxin or beta-blockers. Heart rate ( n = 143,379,796) and physical activity ( n = 23,704,307) intervals were obtained from 53 participants (mean age 75.6 years (s.d. 8.4), 40% women) using a wrist-worn wearable linked to a smartphone for 20 weeks. Heart rates in participants treated with digoxin versus beta-blockers were not significantly different (regression coefficient 1.22 (95% confidence interval (CI) −2.82 to 5.27; P = 0.55); adjusted 0.66 (95% CI −3.45 to 4.77; P = 0.75)). No difference in heart rate was observed between the two groups of patients after accounting for physical activity ( P = 0.74) or patients with high activity levels (≥30,000 steps per week; P = 0.97). Using a convolutional neural network designed to account for missing data, we found that wearable device data could predict New York Heart Association functional class 5 months after baseline assessment similarly to standard clinical measures of electrocardiographic heart rate and 6-minute walk test (F1 score 0.56 (95% CI 0.41 to 0.70) versus 0.55 (95% CI 0.41 to 0.68); P = 0.88 for comparison). The results of this study indicate that digoxin and beta-blockers have equivalent effects on heart rate in atrial fibrillation at rest and on exertion, and suggest that dynamic monitoring of individuals with arrhythmia using wearable technology could be an alternative to in-person assessment. ClinicalTrials.gov identifier: NCT02391337 .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Institute of Cardiovascular Sciences, University of Birmingham, Birmingham, UK.
- Institute of Cancer and Genomic Sciences, University of Birmingham, Birmingham, UK.
- West Midlands NHS Secure Data Environment, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
- NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
- Patient and Public Involvement Team, Birmingham, UK.
- Department of Biostatistics & Health Informatics, King's College London, London, UK.
Förderung
- British Heart Foundation (BHF)
- DH | National Institute for Health Research (NIHR)
- RCUK | MRC | Medical Research Foundation
- Innovative Medicines Initiative (IMI)
- see entry for corresponding author
Zitieren
APA
Gill, S. K., Barsky, A., Guan, X., Bunting, K. V., Karwath, A., Tica, O., Stanbury, M., Haynes, S., Folarin, A., Dobson, R., Kurps, J., Asselbergs, F. W., Grobbee, D. E., Camm, A. J., Eijkemans, M. J. C., Gkoutos, G. V., Kotecha, D., BigData@Heart Consortium, cardAIc group, & RATE-AF trial team (2024). Consumer wearable devices for evaluation of heart rate control using digoxin versus beta-blockers: the RATE-AF randomized trial. Nature Medicine, 30(7), 2030-2036. https://doi.org/10.1038/s41591-024-03094-4
Vancouver
Gill SK, Barsky A, Guan X, Bunting KV, Karwath A, Tica O, et al. Consumer wearable devices for evaluation of heart rate control using digoxin versus beta-blockers: the RATE-AF randomized trial. Nature Medicine. 2024;30(7):2030-2036. doi:10.1038/s41591-024-03094-4
BibTeX
@article{Gill2024,
author = {Gill, Simrat K and Barsky, Andrey and Guan, Xin and Bunting, Karina V and Karwath, Andreas and Tica, Otilia and Stanbury, Mary and Haynes, Sandra and Folarin, Amos and Dobson, Richard and Kurps, Julia and Asselbergs, Folkert W and Grobbee, Diederick E and Camm, A John and Eijkemans, Marinus J C and Gkoutos, Georgios V and Kotecha, Dipak and BigData@Heart Consortium, BigData@Heart Consortium and cardAIc group, cardAIc group and RATE-AF trial team, RATE-AF trial team},
title = {Consumer wearable devices for evaluation of heart rate control using digoxin versus beta-blockers: the RATE-AF randomized trial},
journal = {Nature Medicine},
year = {2024},
volume = {30},
number = {7},
pages = {2030--2036},
doi = {10.1038/s41591-024-03094-4}
}