Fachartikel in der Zeitschrift Microsystems & Nanoengineering, online erschienen am 07.06.2024. Verfasst von Jiajun Meng und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics, University of Melbourne, Victoria, Australia. Die Arbeit wurde bisher 68-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Defence Science Institute, Department of Education and Training | Australian Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Smart, low-cost and portable gas sensors are highly desired due to the importance of air quality monitoring for environmental and defense-related applications. Traditionally, electrochemical and nondispersive infrared (IR) gas sensors are designed to detect a single specific analyte. Although IR spectroscopy-based sensors provide superior performance, their deployment is limited due to their large size and high cost. In this study, a smart, low-cost, multigas sensing system is demonstrated consisting of a mid-infrared microspectrometer and a machine learning algorithm. The microspectrometer is a metasurface filter array integrated with a commercial IR camera that is consumable-free, compact ( ~ 1 cm 3 ) and lightweight ( ~ 1 g). The machine learning algorithm is trained to analyze the data from the microspectrometer and predict the gases present. The system detects the greenhouse gases carbon dioxide and methane at concentrations ranging from 10 to 100% with 100% accuracy. It also detects hazardous gases at low concentrations with an accuracy of 98.4%. Ammonia can be detected at a concentration of 100 ppm. Additionally, methyl-ethyl-ketone can be detected at its permissible exposure limit (200 ppm); this concentration is considered low and nonhazardous. This study demonstrates the viability of using machine learning with IR spectroscopy to provide a smart and low-cost multigas sensing platform.

Schlagwörter

Stichwörter der Autor:innen

Micro-opticsOptical sensors

Autor:innen und Institutionen

  • School of Physics, University of Melbourne, Victoria, Australia.
  • Australian Research Council (ARC) Centre of Excellence for Transformative Meta-Optical Systems (TMOS), University of Melbourne, Victoria, Australia.
  • Centre for Advanced Materials & Industrial Chemistry (CAMIC), STEM college, RMIT University, Victoria, Australia.
  • Department of Electrical and Electronic Engineering, University of Melbourne, Victoria, Australia.

ORCID-Profile: Jiajun Meng

Förderung

  • Defence Science Institute
  • Department of Education and Training | Australian Research Council

Zitieren

APA

Meng, J., Balendhran, S., Sabri, Y., Bhargava, S. K., & Crozier, K. B. (2024). Smart mid-infrared metasurface microspectrometer gas sensing system. Microsystems & Nanoengineering, 10(1). https://doi.org/10.1038/s41378-024-00697-2

Vancouver

Meng J, Balendhran S, Sabri Y, Bhargava SK, Crozier KB. Smart mid-infrared metasurface microspectrometer gas sensing system. Microsystems & Nanoengineering. 2024;10(1). doi:10.1038/s41378-024-00697-2

BibTeX
@article{Meng2024,
  author = {Meng, Jiajun and Balendhran, Sivacarendran and Sabri, Ylias and Bhargava, Suresh K and Crozier, Kenneth B},
  title = {Smart mid-infrared metasurface microspectrometer gas sensing system},
  journal = {Microsystems & Nanoengineering},
  year = {2024},
  volume = {10},
  number = {1},
  doi = {10.1038/s41378-024-00697-2}
}
Kostenlos starten →