Multianalyte Detection with Metasurface-Based Midinfrared Microspectrometer
ACS Sensors · 22.11.2024 · 9 (11) · 5839-5847
DOI: 10.1021/acssensors.4c01220 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 30.10.2024. Verfasst von Henry Tan und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics, University of Melbourne, Parkville, Victoria 3010, Australia. Hauptthemen laut MEDLINE: Spectrophotometry, Infrared. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Department of Defence, Australian Government, Australian Research Council, Defence Science Institute.
Abstract (Originalsprache)
Midinfrared (2.5-25 μm) spectroscopy is an ideal tool for identifying chemicals in a nondestructive manner. The traditional platform is a Fourier transform infrared (FTIR) spectrometer, but this is too bulky, expensive, and power-hungry for many applications. There is therefore a growing demand for small, lightweight, and cost-effective microspectrometers for use in the field. One emerging platform is the filter-array detector-array microspectrometer. It pairs a broadband detector array with a thin and rigid array of spectral filters to offer a robust, compact platform for real-time in situ sensing. However, most demonstrations have only focused on identifying a single chemical against a null sample, even though many applications would involve multianalyte detection. In this work, we show a rare attempt at simultaneously tracking multiple analytes with a metasurface filter-array microspectrometer. The metasurface consists of periodic lattices of subwavelength circular apertures in an aluminum layer to create an array of bandpass filters. The filter array is imaged with an off-the-shelf microbolometer via a reverse-lens imaging setup to simultaneously monitor the concentration of ethanol and methanol in gasoline. This represents an important application of fuel quality monitoring. Chemometric models (PLS and SVR) are trained and tested on gasoline blends with ethanol and methanol contents, both ranging from 0% to 20% v/v. A support vector machine regression (SVR) model with a cubic kernel was found to have the lowest combined prediction errors. The root-mean-square-error of prediction (RMSEP) for ethanol and methanol are 1.23% and 1.84% v/v; the corresponding pseudounivariate limit of detection is found to be 4.22% and 6.86% v/v, respectively. This work takes the emerging field of metasurface-based mid-infrared spectrometers from single- to multianalyte detection, thereby considerably expanding their range of potential applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Physics, University of Melbourne, Parkville, Victoria 3010, Australia.
- ARC Centre of Excellence for Transformative Meta-Optical Systems (TMOS), University of Melbourne, Parkville, Victoria 3010, Australia.
- Department of Electrical and Electronic Engineering, University of Melbourne, Parkville, Victoria 3010, Australia.
ORCID-Profile: Jiajun Meng, Kenneth B Crozier
Förderung
- Department of Defence, Australian Government
- Australian Research Council
- Defence Science Institute
Zitieren
APA
Tan, H., Meng, J., & Crozier, K. B. (2024). Multianalyte Detection with Metasurface-Based Midinfrared Microspectrometer. ACS Sensors, 9(11), 5839-5847. https://doi.org/10.1021/acssensors.4c01220
Vancouver
Tan H, Meng J, Crozier KB. Multianalyte Detection with Metasurface-Based Midinfrared Microspectrometer. ACS Sensors. 2024;9(11):5839-5847. doi:10.1021/acssensors.4c01220
BibTeX
@article{Tan2024,
author = {Tan, Henry and Meng, Jiajun and Crozier, Kenneth B},
title = {Multianalyte Detection with Metasurface-Based Midinfrared Microspectrometer},
journal = {ACS Sensors},
year = {2024},
volume = {9},
number = {11},
pages = {5839--5847},
doi = {10.1021/acssensors.4c01220}
}
EUVIMED