Validation of combiomed hipermax-BF model A7101 automatic oscillometric upper-arm sphygmomanometer in general population: AAMI/ESH/ISO universal standard (ISO 81060-2:2018/Amd 1:2020)

Damaris Hernández Véliz, Yamilé Valdés González iD, Nurys Bárbara Armas Rojas, Reinaldo De la Noval García, Jennifer Ringrose iD, Raj Padwal iD

Journal of Human Hypertension · 2024

DOI: 10.1038/s41371-024-00948-9 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Human Hypertension, 2024. Verfasst von Damaris Hernández Véliz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Cardiology and Cardiovascular Surgery, 17th street 702 between A and Paseo Avenue, Havana, 10400, Cuba. Hauptthemen laut MEDLINE: Sphygmomanometers, Blood Pressure Determination, Oscillometry. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluates the accuracy of the Hipermax-BF model A7101 (Combiomed, Havana, Cuba) automatic oscillometric upper-arm sphygmomanometer for office and home use in general population as part of the HEARTS in the Americas initiative. The research was developed according to the Universal Standard AAMI/ESH/ISO ISO 81060-2:2018/Amd 1:2020. The subjects were recruited according to the requirements of age, gender, blood pressure values and upper-arm circumference. The same upper-arm sequential blood pressure measurement method was used. For measurements with the device under test, the 2-piece cuff from 22-44 cm limb circumference range was used. 92 subjects were recruited and 85 were analyzed. Mean age was 44.8 ± 14.7 years, mean upper-arm circumference was 32.3 ± 6.2, and 56.5% were female. For Validation Criterion 1, the mean value ± standard deviation of the differences in readings between the device under test and the reference device was 1.2 ± 4.9/0.8 ± 4.9 mmHg (systolic/diastolic). For both pressures, in criterion 1 the standard requires a mean value of the differences ≤ ± 5 mmHg and a standard deviation ≤ ± 8 mmHg. For Validation Criterion 2, the standard deviation of the mean blood pressure differences per subject was 4.2/4.2 mmHg (systolic/diastolic). According to Table 1 of criterion 2, for the mean values of 1.2/0.8 mmHg (systolic/diastolic), the maximum allowable standard deviation had to be < 6.84 for systolic and < 6.89 for diastolic pressure. The Combiomed Hipermax-BF A7101 automatic sphygmomanometer meets the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018/Amd 1:2020) in the general population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SphygmomanometersBlood Pressure DeterminationOscillometryHumansFemaleMaleAdultMiddle AgedReproducibility of ResultsBlood PressureEquipment DesignPredictive Value of TestsArmAged

Autor:innen und Institutionen

  • Institute of Cardiology and Cardiovascular Surgery, 17th street 702 between A and Paseo Avenue, Havana, 10400, Cuba.
  • Institute of Endocrinology, Zapata street and D street, Havana, 10400, Cuba. gonzalezvaldes1974@gmail.com.
  • University of Alberta, Edmonton, AB, Canada.

ORCID-Profile: Yamilé Valdés González, Jennifer Ringrose, Raj Padwal

Zitieren

APA

Hernández Véliz, D., Valdés González, Y., Armas Rojas, N. B., De la Noval García, R., Ringrose, J., & Padwal, R. (2024). Validation of combiomed hipermax-BF model A7101 automatic oscillometric upper-arm sphygmomanometer in general population: AAMI/ESH/ISO universal standard (ISO 81060-2:2018/Amd 1:2020). Journal of Human Hypertension. https://doi.org/10.1038/s41371-024-00948-9

Vancouver

Hernández Véliz D, Valdés González Y, Armas Rojas NB, De la Noval García R, Ringrose J, Padwal R. Validation of combiomed hipermax-BF model A7101 automatic oscillometric upper-arm sphygmomanometer in general population: AAMI/ESH/ISO universal standard (ISO 81060-2:2018/Amd 1:2020). Journal of Human Hypertension. 2024. doi:10.1038/s41371-024-00948-9

BibTeX
@article{HernndezVliz2024,
  author = {Hernández Véliz, Damaris and Valdés González, Yamilé and Armas Rojas, Nurys Bárbara and De la Noval García, Reinaldo and Ringrose, Jennifer and Padwal, Raj},
  title = {Validation of combiomed hipermax-BF model A7101 automatic oscillometric upper-arm sphygmomanometer in general population: AAMI/ESH/ISO universal standard (ISO 81060-2:2018/Amd 1:2020)},
  journal = {Journal of Human Hypertension},
  year = {2024},
  doi = {10.1038/s41371-024-00948-9}
}
Kostenlos starten →