EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

The Importance of Sample‐to‐Sensor Distance in Quantitative Micro(Paleo‐)Magnetic Analysis

Rosa A. de Boer, Frenk Out, Bertwin M. de Groot, Martha E. Kosters, Lennart V. de Groot

Geochemistry, Geophysics, Geosystems · 2026-06 · 27 (6)

DOI: 10.1029/2025gc012627 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Geochemistry, Geophysics, Geosystems, online erschienen am 10.06.2026. Verfasst von Rosa A. de Boer und 4 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Information on the past of Earth's magnetic field can be retrieved from magnetic grains in rock samples. Micromagnetic Tomography (MMT) is a recently developed method that uses magnetic surface scans from a Quantum Diamond Microscope (QDM) combined with the position of magnetic grains in rock samples to calculate the magnetic moments of those grains. An important parameter for these calculations is the sample‐to‐sensor distance during the magnetic measurements. Until recently, sample placement in the QDM was typically done manually. To improve sample placement, we developed an automated sample placement system (JAMES). JAMES eases the sample placement process by enabling the positioning of the sample in the x and y direction, as well as positioning of the sample plan‐parallel against the sensor or at a known distance from the sensor with a precision of 1 μm. We evaluated the importance of a known sample‐to‐sensor distance for retrieving quantitative magnetic information with MMT. With a known distance, individual grain magnetic moments and summed intensities (summed magnetic moments of individual grains) can be accurately determined. The sample‐to‐sensor distance is less important for determining directions, when studying isolated grains with dipolar magnetic surface expressions. However, when grains do not meet those conditions, a known sample‐to‐sensor distance is required to determine accurate directions. JAMES is now a standard element in the MMT procedure, ensuring reliable and repeatable magnetic measurements with the QDM. This greatly improves the precision of the magnetic moment calculations in MMT and advances the extraction of magnetic information from rock samples.

Zitieren

APA

Boer, R. A. D., Out, F., Groot, B. M. D., Kosters, M. E., & Groot, L. V. D. (2026). The Importance of Sample‐to‐Sensor Distance in Quantitative Micro(Paleo‐)Magnetic Analysis. Geochemistry, Geophysics, Geosystems, 27(6). https://doi.org/10.1029/2025gc012627

Vancouver

Boer RAD, Out F, Groot BMD, Kosters ME, Groot LVD. The Importance of Sample‐to‐Sensor Distance in Quantitative Micro(Paleo‐)Magnetic Analysis. Geochemistry, Geophysics, Geosystems. 2026;27(6). doi:10.1029/2025gc012627

BibTeX
@article{Boer2026,
  author = {Boer, Rosa A. de and Out, Frenk and Groot, Bertwin M. de and Kosters, Martha E. and Groot, Lennart V. de},
  title = {The Importance of Sample‐to‐Sensor Distance in Quantitative Micro(Paleo‐)Magnetic Analysis},
  journal = {Geochemistry, Geophysics, Geosystems},
  year = {2026},
  volume = {27},
  number = {6},
  doi = {10.1029/2025gc012627}
}
Kostenlos starten →