Kurz gefasst

Fachartikel in der Zeitschrift Analysis & Sensing, online erschienen am 19.06.2025. Verfasst von Karandeep Grover und 3 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 149 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Australian Research Council, Human Frontier Science Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fluorescent sensor arrays address the limitations of a single sensor by leveraging multiple sensing elements to generate unique response patterns for each of the analyte of interest. This approach has emerged as a powerful tool for identifying and analyzing intricate chemical and biological environments using various multivariate analytical tools such as principal component analysis (PCA), linear discriminant analysis (LDA), and hierarchical cluster analysis (HCA). Nevertheless, the extraction of reliable quantitative information from these arrays presents a greater challenge, primarily due to the complexity associated with managing large datasets using conventional regression methods. In recent years, there has been a notable surge in exploring diverse statistical multivariate techniques and deep learning models (including PCA, LDA, HCA, partial least square regression, support vector regression, Gaussian processes regression, and neural networks) as modern regression tools to handle multidimensional data. These analytical tools facilitate the simultaneous acquisition of both qualitative and quantitative information for various analytes using sensor arrays.

Förderung

  • Australian Research Council
  • Human Frontier Science Program

Zitieren

APA

Grover, K., Waseem, M. T., Guo, H., & New, E. J. (2025). Quantitative Analysis of Fluorescent Sensor Arrays. Analysis & Sensing, 5(6). https://doi.org/10.1002/anse.202500052

Vancouver

Grover K, Waseem MT, Guo H, New EJ. Quantitative Analysis of Fluorescent Sensor Arrays. Analysis & Sensing. 2025;5(6). doi:10.1002/anse.202500052

BibTeX
@article{Grover2025,
  author = {Grover, Karandeep and Waseem, Muhammad Tahir and Guo, Haobo and New, Elizabeth J.},
  title = {Quantitative Analysis of Fluorescent Sensor Arrays},
  journal = {Analysis & Sensing},
  year = {2025},
  volume = {5},
  number = {6},
  doi = {10.1002/anse.202500052}
}
Kostenlos starten →