Instrumented Puncture Test of High-Density Polyethylene: Identification of Critical Displacement Points and Effects of Puncture Rate and Sample Thickness
Polymer Science & Technology · 2026-10-27 · 2 (10) · 786-797
DOI: 10.1021/polymscitech.6c00045 ↗At a glance
Journal article in Polymer Science & Technology, published online on 2026-05-04. Written by Ruxin Zang and 4 co-authors. Institution: School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, P. R. China. Cited 3 times so far (Crossref); 57 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: National Natural Science Foundation of China, Jilin Province Science and Technology Development Plan.
Abstract (original language)
Instrumented puncture tests were performed on high-density polyethylene (HDPE) sheets using a flat-ended indenter and a clamped specimen holder. By correlating in situ morphology with puncture force–displacement curves, a consistent set of characteristic displacements was identified for a range of samples with different thicknesses. DC marks the critical displacement where a bending-to-stretching transition, accompanied by stress concentration, drawing of the crown wall, and the onset of microfibrillation, sets in. DD corresponds to the displacement where the maximum force within the fibrillation-dominated regime is reached. A puncture step-cycle test protocol separated recoverable and residual displacements, quantitatively validating the inferred elastoplastic sequence. Based on an energy partition at DC, the critical energy (UC), total absorbed energy (Utotal), and plastic dissipation energy (UP) were determined, and a puncture-specific ductile ratio (D.R.p) was proposed to quantify ductile energy dissipation. Under the present experimental conditions, systematic variations in puncture rate (2–800 mm/min) and specimen thickness (0.47–2.63 mm) reveal two critical thresholds: a transition from quasi-static to rate-dominated response at approximately 80 mm/min and a plate-like to film-like mechanism boundary at approximately 1.2 mm. These results establish a physical framework for mechanistic interpretation and ductility quantification in the puncture behavior of polymers.
Subjects
Author keywords
Authors and institutions
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, P. R. China.
- State Key Laboratory of Polymer Science and Technology, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China.
- Railway Engineering Research Institute, China Academy of Railway Sciences Corporation Limited, Beijing 100081, P.R. China.
- Hebei Tieke Yichen New Materials Technology Co., Ltd., Shijiazhuang 052160, P. R. China.
ORCID profiles: Zhiyong Jiang, Yongfeng Men
Funding
- National Natural Science Foundation of China
- Jilin Province Science and Technology Development Plan
Cite
APA
Zang, R., Dong, Q., Guo, Y., Jiang, Z., & Men, Y. (2026). Instrumented Puncture Test of High-Density Polyethylene: Identification of Critical Displacement Points and Effects of Puncture Rate and Sample Thickness. Polymer Science & Technology, 2(10), 786-797. https://doi.org/10.1021/polymscitech.6c00045
Vancouver
Zang R, Dong Q, Guo Y, Jiang Z, Men Y. Instrumented Puncture Test of High-Density Polyethylene: Identification of Critical Displacement Points and Effects of Puncture Rate and Sample Thickness. Polymer Science & Technology. 2026;2(10):786-797. doi:10.1021/polymscitech.6c00045
BibTeX
@article{Zang2026,
author = {Zang, Ruxin and Dong, Quanxiao and Guo, Yubao and Jiang, Zhiyong and Men, Yongfeng},
title = {Instrumented Puncture Test of High-Density Polyethylene: Identification of Critical Displacement Points and Effects of Puncture Rate and Sample Thickness},
journal = {Polymer Science & Technology},
year = {2026},
volume = {2},
number = {10},
pages = {786--797},
doi = {10.1021/polymscitech.6c00045}
}
EUVIMED