EUVIMEDOpdag EUVIMED
Crossref

Radiative Cooling Limits Collisional Heating of Large Ions

Austin W. Green, Zachary M. Miller, Evan R. Williams, James S. Prell

Journal of the American Society for Mass Spectrometry · 2026-11-14

DOI: 10.1021/jasms.6c00376 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, published online on 2026-11-14. Written by Austin W. Green and 3 co-authors. 93 references. Funded by: Division of Chemistry, National Institute of General Medical Sciences.

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Activation of ions inside a mass spectrometer to induce dissociation or conformational changes can be a powerful way to investigate their structure. Although the most common way to activate ions in contemporary instruments is by collisions with a neutral buffer gas, ions also constantly exchange photons with the ambient radiation field of the instrument. In blackbody infrared radiative dissociation (BIRD) experiments performed in Fourier-transform ion cyclotron resonance or ion trap instruments at low pressure, radiative energy exchange alone can be sufficient to dissociate or unfold ions on the upper-millisecond to several-minute timescale, depending on the thermochemical barrier and radiation temperature. Collisional activation, as implemented in most commercial platforms, typically occurs on the microsecond- to few-millisecond timescale, a roughly thousandfold shorter kinetic window than in BIRD experiments. Radiative energy exchange effects on collisional heating and cooling for large biomolecular ions in these experiments are poorly understood, and computing radiative energy exchange rates for ions >∼1 MDa has been intractable due to the enormous density of states of these ions. Here, we introduce an algorithm for computing radiative energy exchange rates for large ions as a function of ion mass, composition, and initial vibrational temperature. Scaling of radiative emission rates with ion size and vibrational temperature, and the competition between radiative cooling and collisional heating, are studied by incorporating results from this algorithm into the IonSPA software. Implications for thermochemical CID/CIU barrier determination for large ions and practical limitations for collisional heating of multi-MDa- to GDa-sized ions in charge detection mass spectrometry are also discussed.

Funding

  • Division of Chemistry
  • National Institute of General Medical Sciences

Cite

APA

Green, A. W., Miller, Z. M., Williams, E. R., & Prell, J. S. (2026). Radiative Cooling Limits Collisional Heating of Large Ions. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.6c00376

Vancouver

Green AW, Miller ZM, Williams ER, Prell JS. Radiative Cooling Limits Collisional Heating of Large Ions. Journal of the American Society for Mass Spectrometry. 2026. doi:10.1021/jasms.6c00376

BibTeX
@article{Green2026,
  author = {Green, Austin W. and Miller, Zachary M. and Williams, Evan R. and Prell, James S.},
  title = {Radiative Cooling Limits Collisional Heating of Large Ions},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2026},
  doi = {10.1021/jasms.6c00376}
}
Start for free →