EUVIMEDOpdag EUVIMED
Crossref

Retention-Time Bridging across Gradients for LC-HRMS Feature Correspondence

Wentao Zhu iD, Elle Harwood, Daniel Raftery iD

Journal of the American Society for Mass Spectrometry · 2026-11-04 · 37 (11) · 2731-2741

DOI: 10.1021/jasms.6c00226 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, published online on 2026-10-22. Written by Wentao Zhu and 2 co-authors. Institution: Northwest Metabolomics Research Center, Department of Anesthesiology and Pain Medicine, University of Washington, Seattle, Washington98109, United St…. Major MEDLINE topics: Liquid Chromatography-Mass Spectrometry, Tandem Mass Spectrometry, Metabolomics. 33 references. Funded by: NIA NIH HHS, NIDDK NIH HHS, NIAMS NIH HHS.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Untargeted liquid chromatography–high-resolution mass spectrometry (LC–HRMS) supports high-throughput metabolomics, but rapid gradients can compress chromatographic separation and limit downstream annotation. A practical annotation strategy is to analyze all samples using a rapid untargeted method and then reinject selected biological and pooled quality-control (QC) samples under a longer-gradient method to improve separation, MS/MS acquisition, and standard-based confirmation. Because short- and long-gradient feature tables cannot be matched reliably by m/z alone, we developed RTBridge, a same-sample, feature-table-based retention-time (RT) bridging workflow that establishes feature correspondence without requiring structural descriptors or quantitative structure–retention relationship models. Unique anchors were selected using within-method mass uniqueness, cross-method mass agreement, and an abundance-concordance score (ACS). Six empirical RT-transfer models were evaluated: linear regression, piecewise linear interpolation, locally estimated scatterplot smoothing (LOESS), piecewise cubic Hermite interpolation (PCHIP), spline/generalized additive modeling (GAM), and monotone GAM. Using all selected mode-specific anchors, PCHIP produced 5,595 primary feature pairs across four matrix/mode data sets, with a mean median RT error of 0.0232 min. GAM-based residual screening reduced the number of selected training anchors from 1,518 to 1,185, primary-pair recovery from 5,595 to 4,867, and verification support from 161 to 151, while decreasing the mean median RT error to 0.0212 min. We therefore recommend PCHIP RT transfer using all selected mode-specific anchors without residual-based hard deletion, followed by abundance-concordance ranking. RTBridge establishes feature correspondence rather than metabolite identification. Potential extensions include platform or column transfer, batch harmonization, cross-matrix correspondence, and interlaboratory integration but will require direct experimental validation.

Subjects

MeSH terms (MEDLINE)

Liquid Chromatography-Mass SpectrometryTandem Mass SpectrometryMetabolomicsChromatography, Liquid

Author keywords

LC-HRMSabundance concordancecross-gradient bridgingretention-time transferuntargeted metabolomics

Authors and institutions

  • Northwest Metabolomics Research Center, Department of Anesthesiology and Pain Medicine, University of Washington, Seattle, Washington98109, United States.
  • Mitochondria and Metabolism Center, Department of Anesthesiology and Pain Medicine, University of Washington, Seattle, Washington98109, United States.
  • Fred Hutchinson Cancer Center, Seattle, Washington98109, United States.

ORCID profiles: Wentao Zhu, Daniel Raftery

Funding

  • NIA NIH HHS
  • NIDDK NIH HHS
  • NIAMS NIH HHS
  • National Institute of Diabetes and Digestive and Kidney Diseases
  • National Institute on Aging
  • National Institute of Arthritis and Musculoskeletal and Skin Diseases

Cite

APA

Zhu, W., Harwood, E., & Raftery, D. (2026). Retention-Time Bridging across Gradients for LC-HRMS Feature Correspondence. Journal of the American Society for Mass Spectrometry, 37(11), 2731-2741. https://doi.org/10.1021/jasms.6c00226

Vancouver

Zhu W, Harwood E, Raftery D. Retention-Time Bridging across Gradients for LC-HRMS Feature Correspondence. Journal of the American Society for Mass Spectrometry. 2026;37(11):2731-2741. doi:10.1021/jasms.6c00226

BibTeX
@article{Zhu2026,
  author = {Zhu, Wentao and Harwood, Elle and Raftery, Daniel},
  title = {Retention-Time Bridging across Gradients for LC-HRMS Feature Correspondence},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2026},
  volume = {37},
  number = {11},
  pages = {2731--2741},
  doi = {10.1021/jasms.6c00226}
}
Start for free →