EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

An Energetic-Control Framework for Electrospray Ionization Using Thermometer Ions

Max T G M Derks iD, Jana Roithová

Journal of the American Society for Mass Spectrometry · 2026-11-04 · 37 (11) · 2678-2687

DOI: 10.1021/jasms.6c00109 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, published online on 2026-10-01. Written by Max T G M Derks and 1 co-authors. Institution: Institute for Molecules and Materials, Radboud University, Heyendaalseweg 135, Nijmegen6525 AJ, The Netherlands. 34 references. The full text is freely available (open access, CC BY 4.0). Funded by: Nederlandse Organisatie voor Wetenschappelijk Onderzoek.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Electrospray ionization mass spectrometry (ESI-MS) is increasingly used to investigate chemical reactivity. During these experiments, source conditions are frequently adjusted, either deliberately or as part of routine method optimization. However, the energetic consequences of these changes are rarely known, meaning that experiments may unknowingly be performed under different energetic conditions. Consequently, differences observed between experiments may reflect changes in ion activation rather than changes in solution or droplet chemistry, particularly when reactive intermediates or labile species are investigated. Here, we establish a practical, source-specific energetic-control framework using thermometer ions to provide an independent relative energetic reference for a defined electrospray source. A multivariate Design of Experiments revealed that the energetic landscape is governed by strong interactions between source parameters, making the energetic consequences of changing source settings difficult to anticipate and potentially variable between nominally similar experiments. The framework also identified operating regimes in which differential ion transmission distorted the apparent energetic response. After identifying and excluding these transmission-distorted regions, the remaining energetic landscape was accurately described by a predictive multivariate model. The resulting framework provides an independent energetic reference that can be established alongside chemical measurements to distinguish source-induced energetic effects from genuine chemical transformations. We therefore propose that, analogous to routine mass calibration, the energetic response of an electrospray source should be experimentally characterized whenever ion internal energy may influence the observed chemistry.

Subjects

Author keywords

Design of experimentsElectrospray ionizationFlow rate effectsInternal energy calibrationIon activationSurvival yieldThermometer ions

Authors and institutions

  • Institute for Molecules and Materials, Radboud University, Heyendaalseweg 135, Nijmegen6525 AJ, The Netherlands.

ORCID profiles: Max T G M Derks

Funding

  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Cite

APA

Derks, M. T. G. M., & Roithová, J. (2026). An Energetic-Control Framework for Electrospray Ionization Using Thermometer Ions. Journal of the American Society for Mass Spectrometry, 37(11), 2678-2687. https://doi.org/10.1021/jasms.6c00109

Vancouver

Derks MTGM, Roithová J. An Energetic-Control Framework for Electrospray Ionization Using Thermometer Ions. Journal of the American Society for Mass Spectrometry. 2026;37(11):2678-2687. doi:10.1021/jasms.6c00109

BibTeX
@article{Derks2026,
  author = {Derks, Max T G M and Roithová, Jana},
  title = {An Energetic-Control Framework for Electrospray Ionization Using Thermometer Ions},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2026},
  volume = {37},
  number = {11},
  pages = {2678--2687},
  doi = {10.1021/jasms.6c00109}
}
Start for free →