Simulation Study of a Hyperbolic Linear Ion Trap with Asymmetric Curvature Radii
Journal of the American Society for Mass Spectrometry · 2026-01-07 · 37 (1) · 216-225
DOI: 10.1021/jasms.5c00307 ↗At a glance
Journal article in Journal of the American Society for Mass Spectrometry, published online on 2025-12-16. Written by Yang Li and 10 co-authors. Institution: Anhui Province Key Laboratory of Medical Physics and Technology, Hefei Cancer Hospital of CAS, Institute of Health and Medical Technology, Hefei Inst…. Cited 2 times so far (Crossref); 35 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Hefei Institutes of Physical Science, Chinese Academy of Sciences, National Natural Science Foundation of China, Anhui Provincial Key Research and Development Plan.
Abstract (original language)
Linear ion traps (LITs) with simplified geometries have shown potential for miniaturized mass spectrometry systems, though structural simplifications often introduce nonlinear higher-order fields that compromise performance. This study investigates asymmetric hyperbolic electrode modifications to address the inherent 50% detection efficiency limitation in miniaturized LITs caused by bidirectional ion ejection. The research employed numerical simulations to evaluate a geometrically modified LIT design. Electrode asymmetry was introduced through independent adjustments of vertex curvature radii and bending angles in opposing x-direction electrodes, creating an asymmetric trapping field. Structural optimization involved initial x-axis elongation of a centrosymmetric ion trap followed by controlled geometric modifications. Field analysis confirmed the incorporation of odd-order multipole components through these adjustments. Experimental results demonstrated approximately 90% ion ejection efficiency from a single trap side when combining higher-order odd and even multipole fields. This work provides valuable insights into the design of asymmetric ion traps, offering a practical solution for high-performance portable MS development.
Subjects
Author keywords
Authors and institutions
- Anhui Province Key Laboratory of Medical Physics and Technology, Hefei Cancer Hospital of CAS, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, 230031 Hefei,…
- University of Science and Technology of China, 230026 Hefei, China.
ORCID profiles: Yang Li, Chengyin Shen, Chaoqun Huang, Yannan Chu
Funding
- Hefei Institutes of Physical Science, Chinese Academy of Sciences
- National Natural Science Foundation of China
- Anhui Provincial Key Research and Development Plan
- Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument
Cite
APA
Li, Y., Luo, Y., Kong, L., Hao, J., Wei, P., Xia, L., Liu, Y., Zhang, Q., Shen, C., Huang, C., & Chu, Y. (2026). Simulation Study of a Hyperbolic Linear Ion Trap with Asymmetric Curvature Radii. Journal of the American Society for Mass Spectrometry, 37(1), 216-225. https://doi.org/10.1021/jasms.5c00307
Vancouver
Li Y, Luo Y, Kong L, Hao J, Wei P, Xia L, et al. Simulation Study of a Hyperbolic Linear Ion Trap with Asymmetric Curvature Radii. Journal of the American Society for Mass Spectrometry. 2026;37(1):216-225. doi:10.1021/jasms.5c00307
BibTeX
@article{Li2026,
author = {Li, Yang and Luo, Yuanjiang and Kong, Lingwen and Hao, Jiahuan and Wei, Pingyan and Xia, Lei and Liu, Yawei and Zhang, Qiangling and Shen, Chengyin and Huang, Chaoqun and Chu, Yannan},
title = {Simulation Study of a Hyperbolic Linear Ion Trap with Asymmetric Curvature Radii},
journal = {Journal of the American Society for Mass Spectrometry},
year = {2026},
volume = {37},
number = {1},
pages = {216--225},
doi = {10.1021/jasms.5c00307}
}