EUVIMEDObjevte EUVIMED
Crossref

Theoretical Study Synchronized Reverse Scan Collision-Induced Dissociation in Digital Linear Ion Trap

Weimin Wang iD, Zhichao Xie, Fuxing Xu iD, Li Ding iD, Chuan-Fan Ding

Journal of the American Society for Mass Spectrometry · 2025-12-03 · 36 (12) · 2666-2674

DOI: 10.1021/jasms.5c00277 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, published online on 2025-10-28. Written by Weimin Wang and 4 co-authors. Institution: School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, China. Cited 2 times so far (Crossref); 40 references. Funded by: National Key Research and Development Program of China, Ningbo Yongjiang Innovation Team.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

The effectiveness of collision-induced dissociation (CID) in ion trap mass spectrometry (ITMS) is limited by a low-mass cutoff and weak fragmentation yields. Theoretically, the q value is optimized to balance the fractional product ion mass range with adequate energy deposition to improve fragment ion detection in the CID process; however, many promising technologies still depend on the traditional sinusoidal waveform-driven IT. Additionally, traditional CID-based multistage mass spectrometry (MSn) experiments on ITMS rely on complex and time-consuming "tuning" to optimize CID for a particular ion. The digital ion trap (DIT) has a very promising application field in MSn analysis, because of its many unique features. Herein, we conducted a theoretical and experimental investigation of a developed synchronized reverse scan-CID (SRS-CID) using a digital linear ion trap. Specifically, (1) simulations and experiments demonstrated that in the SRS-CID, ions were sequentially scanned from high to low m/z value via the resonance excitation point (qexcitation), producing multiple fragment ions without the need to know the m/z value or complex radiofrequency (rf) tuning of each product ion. The simulations demonstrated that the heating rate in the SRS-CID could reach 0.022 eV/μs. The experiments demonstrated that the optimal reverse scan speed was -0.053 ns/step. (2) We preliminary increased the period by a fixed value (Tstep) to control qexcitation to study the molecule fragmentation approach. Different mass spectra were obtained by controlling texcitation with a fixed Tstep. (3) This paper introduces the phase space method to study the motion trajectories of precursor ions and daughter ions. The calculations used and the entire program were uploaded to GitHub. (4) Changing the duty cycle to advantageously shift qexcitation improved the heating rate (0.033 eV/μs) in SRS-CID. Overall, we demonstrated the effectiveness of the developed SRS-CID technique in fragment ion analysis via theoretical derivation, simulation, and experimentation. Furthermore, DIT mass spectrometry was advantageous in tandem mass spectrometry analysis by facilitating modulation of the driving rf period.

Subjects

Author keywords

Collision-induced dissociationDigital ion trap mass spectrometryPhase space analysisSIMION simulation

Authors and institutions

  • School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, China.
  • Key Laboratory of Advanced Mass spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass spectrometry, Ningbo University, Ningbo 315211, China.

ORCID profiles: Weimin Wang, Fuxing Xu, Li Ding

Funding

  • National Key Research and Development Program of China
  • Ningbo Yongjiang Innovation Team

Cite

APA

Wang, W., Xie, Z., Xu, F., Ding, L., & Ding, C. F. (2025). Theoretical Study Synchronized Reverse Scan Collision-Induced Dissociation in Digital Linear Ion Trap. Journal of the American Society for Mass Spectrometry, 36(12), 2666-2674. https://doi.org/10.1021/jasms.5c00277

Vancouver

Wang W, Xie Z, Xu F, Ding L, Ding CF. Theoretical Study Synchronized Reverse Scan Collision-Induced Dissociation in Digital Linear Ion Trap. Journal of the American Society for Mass Spectrometry. 2025;36(12):2666-2674. doi:10.1021/jasms.5c00277

BibTeX
@article{Wang2025,
  author = {Wang, Weimin and Xie, Zhichao and Xu, Fuxing and Ding, Li and Ding, Chuan-Fan},
  title = {Theoretical Study Synchronized Reverse Scan Collision-Induced Dissociation in Digital Linear Ion Trap},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2025},
  volume = {36},
  number = {12},
  pages = {2666--2674},
  doi = {10.1021/jasms.5c00277}
}
Start for free →