EUVIMEDOpdag EUVIMED
Crossref

Profiling Multiple Steroid Subclasses Enabled by Rounded Turn SLIM Ion Mobility

Cole L Frank, Breland M Jones, Emmaleigh Efird, Makenna Hoover, Selena Kingsley, Heidi M Sabatini, Christopher D Chouinard iD

Journal of the American Society for Mass Spectrometry · 2025

DOI: 10.1021/jasms.5c00218 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2025. Written by Cole L Frank and 6 co-authors. Institution: Clemson University, Department of Chemistry, Clemson, South Carolina 29634, United States. Major MEDLINE topics: Steroids, Ion Mobility Spectrometry, Mass Spectrometry. Cited 2 times so far (Crossref); 78 references. Funded by: Partnership for Clean Competition, Clemson University, National Science Foundation.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Ion mobility-mass spectrometry has shown tremendous potential for improving the analysis of various subclasses of steroids. Its speed and ability to separate isobaric and isomeric species makes it ideal for biomedical, clinical, food, environmental, and antidoping analyses. But while other high-resolution ion mobility (HRIM) techniques have begun to see increased use in steroidomics, Structures for Lossless Ion Manipulations (SLIM) is a relative newcomer to the field. HRIM methods are generally challenged with low molecular weight (MW < 400) analysis, but a recently developed SLIM platform has incorporated rounded turns, helium buffer gas, and increased SLIM RF frequency to enable improved low mass transmission. In the present work, we investigate this low mass-tailored SLIM system for the analysis of anabolic androgens, bile acids, endocrine hormones, and ketosteroids. Linear regression-corrected SLIMCCSHe (CCS = collision cross section) values show excellent agreement with values obtained via direct measurement with a drift tube instrument but also underlie the importance of using class- and adduct-specific correction factors. Next, separation performance was evaluated for a range of challenging isomers and demonstrated good resolution for species with ΔCCS of

Subjects

MeSH terms (MEDLINE)

SteroidsIon Mobility SpectrometryMass SpectrometryIsomerism

Author keywords

Ion Mobility-Mass SpectrometrySteroidsStructures for Lossless Ion Manipulations (SLIM)

Substances

Steroids

Authors and institutions

  • Clemson University, Department of Chemistry, Clemson, South Carolina 29634, United States.

ORCID profiles: Christopher D Chouinard

Funding

  • Partnership for Clean Competition
  • Clemson University
  • National Science Foundation
  • Agilent Technologies
  • MOBILion Systems, Inc.

Cite

APA

Frank, C. L., Jones, B. M., Efird, E., Hoover, M., Kingsley, S., Sabatini, H. M., & Chouinard, C. D. (2025). Profiling Multiple Steroid Subclasses Enabled by Rounded Turn SLIM Ion Mobility. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.5c00218

Vancouver

Frank CL, Jones BM, Efird E, Hoover M, Kingsley S, Sabatini HM, et al. Profiling Multiple Steroid Subclasses Enabled by Rounded Turn SLIM Ion Mobility. Journal of the American Society for Mass Spectrometry. 2025. doi:10.1021/jasms.5c00218

BibTeX
@article{Frank2025,
  author = {Frank, Cole L and Jones, Breland M and Efird, Emmaleigh and Hoover, Makenna and Kingsley, Selena and Sabatini, Heidi M and Chouinard, Christopher D},
  title = {Profiling Multiple Steroid Subclasses Enabled by Rounded Turn SLIM Ion Mobility},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2025},
  doi = {10.1021/jasms.5c00218}
}
Start for free →