EUVIMEDOpdag EUVIMED
Crossref

High-Throughput Detection and Quantitation of Metal Contamination with Acoustic Ejection Mass Spectrometry

Alandra Quinn, Kenneth J Dirico, Simon Berritt iD, Thomas R Covey, Jamie Tourville, Brendon Kapinos, Bhagyashree Khunte, Pablo Trigo-Mourino, Hui Zhang iD, Matthew D Troutman, Chang Liu iD

Journal of the American Society for Mass Spectrometry · 2025

DOI: 10.1021/jasms.5c00182 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2025. Written by Alandra Quinn and 10 co-authors. Institution: Pfizer Global Research and Development, Groton, Connecticut 06340, United States. Major MEDLINE topics: High-Throughput Screening Assays, Mass Spectrometry, Metals. Cited 1 times so far (Crossref); 31 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Metal-catalyzed reactions are integral to medicinal chemistry, yet residual metal contamination in synthesized compounds poses significant challenges for drug discovery. Residual metal ions in reaction products can interfere with biological assays, leading to false positives and unreliable potency results. Traditional techniques like ICP-MS and XRF, while effective, fail to meet the throughput demands of large-scale synthesis. Here, we present a novel approach using Acoustic Ejection Mass Spectrometry (AEMS) for the high-speed detection and quantitation of metal contaminants. Utilizing EDTA as a chelator, the high-resolution AEMS platform identified with high confidence the ten metals most utilized in medicinal chemistry. The platform's high reproducibility, sensitivity, and wide dynamic range allow for the quantitation of metal ions with lower limit of quantification (LLOQ) in the single-digit ppm level. This novel approach meets the high-throughput requirements of modern synthetic chemistry and compound library assessments, streamlining the identification and elimination of metal contaminants.

Subjects

MeSH terms (MEDLINE)

High-Throughput Screening AssaysMass SpectrometryMetalsReproducibility of ResultsLimit of DetectionEdetic AcidChelating Agents

Substances

MetalsEdetic AcidChelating Agents

Authors and institutions

  • Pfizer Global Research and Development, Groton, Connecticut 06340, United States.
  • SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada.

ORCID profiles: Simon Berritt, Hui Zhang, Chang Liu

Cite

APA

Quinn, A., Dirico, K. J., Berritt, S., Covey, T. R., Tourville, J., Kapinos, B., Khunte, B., Trigo-Mourino, P., Zhang, H., Troutman, M. D., & Liu, C. (2025). High-Throughput Detection and Quantitation of Metal Contamination with Acoustic Ejection Mass Spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.5c00182

Vancouver

Quinn A, Dirico KJ, Berritt S, Covey TR, Tourville J, Kapinos B, et al. High-Throughput Detection and Quantitation of Metal Contamination with Acoustic Ejection Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2025. doi:10.1021/jasms.5c00182

BibTeX
@article{Quinn2025,
  author = {Quinn, Alandra and Dirico, Kenneth J and Berritt, Simon and Covey, Thomas R and Tourville, Jamie and Kapinos, Brendon and Khunte, Bhagyashree and Trigo-Mourino, Pablo and Zhang, Hui and Troutman, Matthew D and Liu, Chang},
  title = {High-Throughput Detection and Quantitation of Metal Contamination with Acoustic Ejection Mass Spectrometry},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2025},
  doi = {10.1021/jasms.5c00182}
}
Start for free →