EUVIMEDOpdag EUVIMED
Crossref

The Impact of the Mass Analyzer and Tissue Section Thickness on Spatial N -Glycomics with MALDI-MSI

Dušan Veličković iD, Marija Veličković, Christopher L O'Connor, Markus Bitzer, Christopher Anderton iD

Journal of the American Society for Mass Spectrometry · 2025

DOI: 10.1021/jasms.4c00494 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2025. Written by Dušan Veličković and 4 co-authors. Institution: Environmental Molecular Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States. Major MEDLINE topics: Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Polysaccharides, Glycomics. Cited 10 times so far (Crossref); 28 references. Funded by: Environmental Molecular Sciences Laboratory, National Institute of Diabetes and Digestive and Kidney Diseases.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

We compared matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) spatial N -glycomics data sets from Fourier-transform ion cyclotron resonance (FTICR) and orthogonal accelerated time-of-flight (timsTOF) mass spectrometers of FFPE preserved human kidney samples. We also tested different tissue section thicknesses. In these analyses, we assessed the impact of the mass analyzer and tissue section thickness on N -glycan coverage, sensitivity, and histological alignment. Our results indicate negligible differences in N -glycan coverage between the two mass analyzers, where N -glycan annotation numbers remained consistent and were highly reproducible. The timsTOF-MS analyses demonstrated significant advantages with higher duty cycles and better lateral resolution, allowing for finer spatial resolution without compromising signal integrity. Specifically, timsTOF was able to generate detailed MALDI-MS images at 20 μm step size, accurately identifying N -glycan Hex:5 HexNAc:5 dHex:1 as a tubular-specific marker without observable delocalization. Despite minor annotation discrepancies, where only three species detected by FTICR were not detected by using timsTOF, and a few false-positive annotations from the timsTOF analysis attributed to lower mass resolving power, the overall consistency between the instruments was high. Importantly, tissue section thickness did not affect analysis sensitivity in the timsTOF analyses, with the average glycan signal intensity remaining stable between 7 and 2 μm sections. These findings demonstrate that 2 μm thick tissue slices can be effectively used in spatial N -glycomics workflows, maintaining sensitivity while enhancing confidence in pathohistological evaluations.

Subjects

MeSH terms (MEDLINE)

Spectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationPolysaccharidesGlycomicsHumansKidneyFourier AnalysisReproducibility of Results

Substances

Polysaccharides

Authors and institutions

  • Environmental Molecular Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • University of Michigan, Department of Internal Medicine, Ann Arbor, Michigan 48109, United States.

ORCID profiles: Dušan Veličković, Christopher Anderton

Funding

  • Environmental Molecular Sciences Laboratory
  • National Institute of Diabetes and Digestive and Kidney Diseases

Cite

APA

Veličković, D., Veličković, M., O'Connor, C. L., Bitzer, M., & Anderton, C. (2025). The Impact of the Mass Analyzer and Tissue Section Thickness on Spatial N -Glycomics with MALDI-MSI. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.4c00494

Vancouver

Veličković D, Veličković M, O'Connor CL, Bitzer M, Anderton C. The Impact of the Mass Analyzer and Tissue Section Thickness on Spatial N -Glycomics with MALDI-MSI. Journal of the American Society for Mass Spectrometry. 2025. doi:10.1021/jasms.4c00494

BibTeX
@article{Velikovi2025,
  author = {Veličković, Dušan and Veličković, Marija and O'Connor, Christopher L and Bitzer, Markus and Anderton, Christopher},
  title = {The Impact of the Mass Analyzer and Tissue Section Thickness on Spatial N -Glycomics with MALDI-MSI},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2025},
  doi = {10.1021/jasms.4c00494}
}
Start for free →