EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Analysis of Fentanyl and Fentanyl Analogs Using Atmospheric Pressure Chemical Ionization Gas Chromatography–Mass Spectrometry (APCI-GC-MS)

Karen A Reyes Monroy, Richard McCrary, Isabelle Parry, Catherine Webber, Teresa D Golden iD, Guido F Verbeck iD

Journal of the American Society for Mass Spectrometry · 2025-03-05 · 36 (3) · 587-600

DOI: 10.1021/jasms.4c00455 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, published online on 2025-02-03. Written by Karen A Reyes Monroy and 5 co-authors. Institution: Department of Chemistry, University of North Texas, 1155 Union Circle #30570, Denton, Texas 76203, United States. Major MEDLINE topics: Fentanyl, Gas Chromatography-Mass Spectrometry, Analgesics, Opioid. Cited 4 times so far (Crossref); 58 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

High Resolution Image Download MS PowerPoint Slide Illicit fentanyl and fentanyl analogs are a growing concern in the United States as opioid related deaths rise. Given that fentanyl analogs are readily obtained by modifying the structure of fentanyl, illicit fentanyl analogs appearing on the black market often contain similar structures, making analogue differentiation and identification difficult. Thus, obtaining both precursor and product ion data during analysis is becoming increasingly valuable in fentanyl analog characterization. In this paper, we provide GC column retention time, precursor, and product ion mass spectrum data for 74 fentanyl analogs that were analyzed using atmospheric pressure chemical ionization-gas chromatography–mass spectrometry (APCI-GC-MS) utilizing a triple quadrupole mass analyzer. During analysis, precursor ions underwent collision induced dissociation (CID) by increasing the collision energy (10, 20, 30, 40, and 50 V) throughout a single run. Data reveal that APCI readily produces product ions of the piperidine and N -alkyl chain but rarely provides data on the acyl group. Furthermore, fentanyl analogs with greater substitution at the N -alkyl chain demonstrate a greater preference for dissociation at the N-αC and αC-βC bond, while greater substitution at the amide group leads to fragmentation at the N–C4 bond.

Subjects

MeSH terms (MEDLINE)

FentanylGas Chromatography-Mass SpectrometryAnalgesics, OpioidAtmospheric Pressure

Author keywords

AnalogsAtmospheric Pressure Chemical IonizationFentanylFragmentation AnalysisGas ChromatographyMass Spectrometry

Substances

FentanylAnalgesics, Opioid

Authors and institutions

  • Department of Chemistry, University of North Texas, 1155 Union Circle #30570, Denton, Texas 76203, United States.

ORCID profiles: Teresa D Golden, Guido F Verbeck

Cite

APA

Reyes Monroy, K. A., McCrary, R., Parry, I., Webber, C., Golden, T. D., & Verbeck, G. F. (2025). Analysis of Fentanyl and Fentanyl Analogs Using Atmospheric Pressure Chemical Ionization Gas Chromatography–Mass Spectrometry (APCI-GC-MS). Journal of the American Society for Mass Spectrometry, 36(3), 587-600. https://doi.org/10.1021/jasms.4c00455

Vancouver

Reyes Monroy KA, McCrary R, Parry I, Webber C, Golden TD, Verbeck GF. Analysis of Fentanyl and Fentanyl Analogs Using Atmospheric Pressure Chemical Ionization Gas Chromatography–Mass Spectrometry (APCI-GC-MS). Journal of the American Society for Mass Spectrometry. 2025;36(3):587-600. doi:10.1021/jasms.4c00455

BibTeX
@article{ReyesMonroy2025,
  author = {Reyes Monroy, Karen A and McCrary, Richard and Parry, Isabelle and Webber, Catherine and Golden, Teresa D and Verbeck, Guido F},
  title = {Analysis of Fentanyl and Fentanyl Analogs Using Atmospheric Pressure Chemical Ionization Gas Chromatography–Mass Spectrometry (APCI-GC-MS)},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2025},
  volume = {36},
  number = {3},
  pages = {587--600},
  doi = {10.1021/jasms.4c00455}
}
Start for free →