EUVIMEDObjevte EUVIMED
Crossref

Direct Implementation of MS n Using Frequency Scanning Collision Induced Dissociation in a Digital Ion Trap Mass Spectrometer

Jie Ren, Pingping Chen, Yunjing Zhang iD, Xingli He, Lingfeng Li iD, Peng Li

Journal of the American Society for Mass Spectrometry · 2025-02-05 · 36 (2) · 309-317

DOI: 10.1021/jasms.4c00395 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, published online on 2024-12-23. Written by Jie Ren and 5 co-authors. Institution: School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China. Cited 8 times so far (Crossref); 45 references. Funded by: National Key Research and Development Program of China, National Natural Science Foundation of China, National High Level Hospital Clinical Research Funding.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Tandem mass spectrometry (MSn) is one of the most effective methods to obtain the structures of organic molecules, enabling the observation of multigenerational ion fragments. Collision-induced dissociation (CID) is currently the most mature technique for mass spectrometry analysis. Ion trap mass spectrometry (ITMS) is favored for on-site detection field, due to its ability of MSn analysis with a single trap and its small size. However, conventional MSn analysis in ITMS requires repeated isolation and excitation processes multiple times, causing high complexity of the entire scanning process. Additionally, the fragment ion detection in ITMS is limited by low-mass cutoff (LMCO) and the weak fragmentation yield. In this study, a method named reverse scanning-collision induced dissociation (RS-CID) is proposed, which involves increasing RF and AC frequencies while maintaining RF voltage constant during the CID process. Twelve representative illegal drugs were analyzed adopting this method, enhancing the intensities of low-mass fragment ions compared to conventional dissociation method. Moreover, experimental results with ketamine and methamphetamine show that RS-CID effectively reduces the LMCO effect and slightly improves CID efficiency. It also enables direct acquisition of their multigeneration fragment ions spectra in a single sequence of ion injection, cooling, isolation, RS-CID, cooling, mass scanning and empty. The experiments to distinguish between the isomers ab-4en-pinaca and adb-3en-butinaca as well as the isomeric compounds 5f-cumyl-pegaclone and cumyl-pipetinaca were also successful by this method. In summary, RS-CID enables MSn analysis in a single sequence and improves the low-mass fragment ions intensity. It can simplify workflows, achieve faster analysis and provide more valuable mass spectral information.

Subjects

Author keywords

Digital linear ion trapDissociation efficiencyMSn spectraReverse scanning-collision induced dissociation

Authors and institutions

  • School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China.
  • Suzhou Weimu Intelligent System Co., Ltd., Suzhou 215163, China.

ORCID profiles: Yunjing Zhang, Lingfeng Li

Funding

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • National High Level Hospital Clinical Research Funding

Cite

APA

Ren, J., Chen, P., Zhang, Y., He, X., Li, L., & Li, P. (2025). Direct Implementation of MS n Using Frequency Scanning Collision Induced Dissociation in a Digital Ion Trap Mass Spectrometer. Journal of the American Society for Mass Spectrometry, 36(2), 309-317. https://doi.org/10.1021/jasms.4c00395

Vancouver

Ren J, Chen P, Zhang Y, He X, Li L, Li P. Direct Implementation of MS n Using Frequency Scanning Collision Induced Dissociation in a Digital Ion Trap Mass Spectrometer. Journal of the American Society for Mass Spectrometry. 2025;36(2):309-317. doi:10.1021/jasms.4c00395

BibTeX
@article{Ren2025,
  author = {Ren, Jie and Chen, Pingping and Zhang, Yunjing and He, Xingli and Li, Lingfeng and Li, Peng},
  title = {Direct Implementation of MS n Using Frequency Scanning Collision Induced Dissociation in a Digital Ion Trap Mass Spectrometer},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2025},
  volume = {36},
  number = {2},
  pages = {309--317},
  doi = {10.1021/jasms.4c00395}
}